Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2018 Aug;104(16):1362-1369.
doi: 10.1136/heartjnl-2017-312517. Epub 2018 Feb 5.

Coronary intervention door-to-balloon time and outcomes in ST-elevation myocardial infarction: a meta-analysis

Affiliations
Meta-Analysis

Coronary intervention door-to-balloon time and outcomes in ST-elevation myocardial infarction: a meta-analysis

Chee Yoong Foo et al. Heart. 2018 Aug.

Abstract

Objective: This study aims to determine the relationship between door-to-balloon delay in primary percutaneous coronary intervention and ST-elevation myocardial infarction (MI) outcomes and examine for potential effect modifiers.

Methods: We conducted a systematic review and meta-analysis of prospective observational studies that have investigated the relationship of door-to-balloon delay and clinical outcomes. The main outcomes include mortality and heart failure.

Results: 32 studies involving 299 320 patients contained adequate data for quantitative reporting. Patients with ST-elevation MI who experienced longer (>90 min) door-to-balloon delay had a higher risk of short-term mortality (pooled OR 1.52, 95% CI 1.40 to 1.65) and medium-term to long-term mortality (pooled OR 1.53, 95% CI 1.13 to 2.06). A non-linear time-risk relation was observed (P=0.004 for non-linearity). The association between longer door-to-balloon delay and short-term mortality differed between those presented early and late after symptom onset (Cochran's Q 3.88, P value 0.049) with a stronger relationship among those with shorter prehospital delays.

Conclusion: Longer door-to-balloon delay in primary percutaneous coronary intervention for ST-elevation MI is related to higher risk of adverse outcomes. Prehospital delays modified this effect. The non-linearity of the time-risk relation might explain the lack of population effect despite an improved door-to-balloon time in the USA.

Clinical trial registration: PROSPERO (CRD42015026069).

Keywords: door-to-balloon time; meta-analysis; myocardial infarction; pre-hospital delays; primary percutaneous coronary intervention; reperfusion timeliness.