Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2018 Aug;16(4):237-244.
doi: 10.1016/j.surge.2017.12.003. Epub 2018 Feb 10.

Increased precision of coronal plane outcomes in robotic-assisted total knee arthroplasty: A systematic review and meta-analysis

Affiliations
Meta-Analysis

Increased precision of coronal plane outcomes in robotic-assisted total knee arthroplasty: A systematic review and meta-analysis

Ashim Mannan et al. Surgeon. 2018 Aug.

Abstract

Background: Inaccuracy of component alignment in total knee arthroplasty adversely impacts outcomes. Robotic systems improve translation of pre-operative planning to intra-operative steps, theoretically resulting in greater accuracy and precision. In this study we systematically review literature data of alignment outcomes and apply meta-analysis methods to assess whether robotic-assisted knee arthroplasty provides superior outcomes when compared to conventional knee prostheses.

Methods: A PRISMA compliant search comparing alignment outcomes in robotic vs conventional knee arthroplasty was performed. Primary outcome measures were; number of three degree outliers and mean deviation from a neutral post-operative mechanical axis.

Results: In total, from five studies reporting upon 402 knees, a post-operative mechanical axis malalignment of >3° occurred in 1/181 (0.006%) of robotic knees, and 42/159 (26.4%) of conventional knees with a meta-analysis odds ratio of 0.04 (95% CI 0.01-0.14), p < 0.00001 favouring robotic-assisted instrumentation. Meta-analysis also demonstrated weighted mean differences of post-operative mechanical axis alignment to be significantly more accurate in the robotic knee group: mean difference -0.63 (95% CI: -1.18,-0.08), z = 2.25, p = 0.02. Sensitivity analysis with inclusion of only Level 1 studies showed similar findings.

Conclusions: This systematic review and meta-analysis demonstrates clear evidence of increased accuracy of alignment in robotic-assisted knee arthroplasty with specific regard to reconstituting a neutral mechanical axis and minimising number of outliers in the coronal plane. Further studies and long term data is required in order to conclude on survivorship and functional outcomes.

Keywords: Alignment; Knee arthroplasty; Robotic knee.

PubMed Disclaimer

MeSH terms