Load-sharing through elastic micro-motion accelerates bone formation and interbody fusion
- PMID: 29452282
- PMCID: PMC6008179
- DOI: 10.1016/j.spinee.2018.02.004
Load-sharing through elastic micro-motion accelerates bone formation and interbody fusion
Abstract
Background context: Achieving a successful spinal fusion requires the proper biological and biomechanical environment. Optimizing load-sharing in the interbody space can enhance bone formation. For anterior cervical discectomy and fusion (ACDF), loading and motion are largely dictated by the stiffness of the plate, which can facilitate a balance between stability and load-sharing. The advantages of load-sharing may be substantial for patients with comorbidities and in multilevel procedures where pseudarthrosis rates are significant.
Purpose: We aimed to evaluate the efficacy of a novel elastically deformable, continuously load-sharing anterior cervical spinal plate for promotion of bone formation and interbody fusion relative to a translationally dynamic plate.
Study design/setting: An in vivo animal model was used to evaluate the effects of an elastically deformable spinal plate on bone formation and spine fusion.
Methods: Fourteen goats underwent an ACDF and received either a translationally dynamic or elastically deformable plate. Animals were followed up until 18 weeks and were evaluated by plain x-ray, computed tomography scan, and undecalcified histology to evaluate the rate and quality of bone formation and interbody fusion.
Results: Animals treated with the elastically deformable plate demonstrated statistically significantly superior early bone formation relative to the translationally dynamic plate. Trends in the data from 8 to 18 weeks postoperatively suggest that the elastically deformable implant enhanced bony bridging and fusion, but these enhancements were not statistically significant.
Conclusions: Load-sharing through elastic micro-motion accelerates bone formation in the challenging goat ACDF model. The elastically deformable implant used in this study may promote early bony bridging and increased rates of fusion, but future studies will be necessary to comprehensively characterize the advantages of load-sharing through micro-motion.
Keywords: Anterior; Cervical; Fusion; Load-sharing; Micro-motion; Plate.
Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Figures








Similar articles
-
Stiffness Matters: Part I-The Effects of Plate Stiffness on the Biomechanics of ACDF In Vitro.Spine (Phila Pa 1976). 2018 Sep 15;43(18):E1061-E1068. doi: 10.1097/BRS.0000000000002643. Spine (Phila Pa 1976). 2018. PMID: 29547464
-
Stiffness Matters: Part II-The Effects of Plate Stiffness on Load-Sharing and the Progression of Fusion Following Anterior Cervical Discectomy and Fusion In Vivo.Spine (Phila Pa 1976). 2018 Sep 15;43(18):E1069-E1076. doi: 10.1097/BRS.0000000000002644. Spine (Phila Pa 1976). 2018. PMID: 29557926
-
Anterior cervical fixation: analysis of load-sharing and stability with use of static and dynamic plates.J Bone Joint Surg Am. 2006 Jul;88(7):1566-73. doi: 10.2106/JBJS.E.00305. J Bone Joint Surg Am. 2006. PMID: 16818983 Clinical Trial.
-
Static versus dynamic plating for multilevel anterior cervical discectomy and fusion.Spine J. 2007 Mar-Apr;7(2):188-93. doi: 10.1016/j.spinee.2006.07.004. Epub 2007 Jan 24. Spine J. 2007. PMID: 17321968
-
Dynamic anterior cervical plates.J Am Acad Orthop Surg. 2007 Nov;15(11):640-6. doi: 10.5435/00124635-200711000-00002. J Am Acad Orthop Surg. 2007. PMID: 17989414 Review.
Cited by
-
Posterior spinal instrumentation and decompression with or without cross-link?N Am Spine Soc J. 2021 Nov 17;8:100093. doi: 10.1016/j.xnsj.2021.100093. eCollection 2021 Dec. N Am Spine Soc J. 2021. PMID: 35141657 Free PMC article.
-
Does Screw Number of Zero-profile Implants in Fusion Segment Influence Intervertebral Stability?Orthop Surg. 2024 Oct;16(10):2355-2363. doi: 10.1111/os.14139. Epub 2024 Jun 19. Orthop Surg. 2024. PMID: 38898377 Free PMC article.
-
Histomorphometric Assessment of Non-Decalcified Plastic-Embedded Specimens for Evaluation of Bone Regeneration Using Bone Substitute Materials-A Systematic Review.Materials (Basel). 2024 Dec 30;18(1):119. doi: 10.3390/ma18010119. Materials (Basel). 2024. PMID: 39795764 Free PMC article. Review.
-
Load Share Mapping for Traditional PEEK vs Novel Hybrid PEEK With Expandable Porous Mesh Intervertebral Devices.Int J Spine Surg. 2020 Dec;14(s3):S115-S120. doi: 10.14444/7134. Epub 2020 Oct 29. Int J Spine Surg. 2020. PMID: 33122181 Free PMC article.
-
Critical Evaluation of Biomechanical Principles and Radiographic Indicators for Fusion Assessment in a Novel Conformable Porous Mesh Implant.Int J Spine Surg. 2020 Dec;14(s3):S108-S114. doi: 10.14444/7133. Epub 2020 Oct 29. Int J Spine Surg. 2020. PMID: 33122177 Free PMC article.
References
-
- Krakauer JC, Mckenna MJ, Buderer NF, et al. Bone loss and bone turnover in diabetes. Diabetes. 1995;44:775–82. - PubMed
-
- Rubin MR. Bone cells and bone turnover in diabetes mellitus. Current osteoporosis reports. 2015;13:186–91. - PubMed
-
- Andersen T, Christensen FB, Laursen M, et al. Smoking as a predictor of negative outcome in lumbar spinal fusion. Spine. 2001;26:2623–8. - PubMed
-
- Hadley MN, Reddy SV. Smoking and the human vertebral column: a review of the impact of cigarette use on vertebral bone metabolism and spinal fusion. Neurosurgery. 1997;41:116–24. - PubMed
-
- Costa-Rodrigues J, Reis S, Teixeira S, et al. Dose-dependent inhibitory effects of proton pump inhibitors on human osteoclastic and osteoblastic cell activity. The FEBS journal. 2013;280:5052–64. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources