Transcatheter Closure of Arterial Duct in Infants < 6 kg: Amplatzer Duct Occluder Type I vs Amplatzer Duct Occluder II Additional Sizes
- PMID: 29453685
- DOI: 10.1007/s00246-018-1828-5
Transcatheter Closure of Arterial Duct in Infants < 6 kg: Amplatzer Duct Occluder Type I vs Amplatzer Duct Occluder II Additional Sizes
Abstract
Transcatheter closure of arterial duct (AD) remains challenging in low-weight patients and using Amplatzer Duct Occluder devices is still considered off-label in infants < 6 kg. This study aimed to report a large, single-center experience of percutaneous AD closure in infants < 6 kg as well as to compare the most frequently used devices, Amplatzer Duct Occluder type I (ADO I) and Amplatzer Duct Occluder type II Additional Sizes devices (ADO II-AS) (St. Jude Medical Corp, St. Paul, MN, USA). From March 2000 to March 2017, among the 762 patients submitted to percutaneous closure of AD at our Institution, 33 were infants < 6 kg (age 4.8 ± 2.1 months; weight 5.0 ± 0.9 kg). Fourteen patients (45%) underwent ADO I (Group I) and 19 patients ADO II-AS (Group II) device implantation. AD diameter was 2.6 ± 0.8 (range 1.5-4.0) mm resulting in QP/QS of 2.6 ± 0.0.9 (range 1.1-4.5). Successful device deployment was achieved in all patients without procedural morbidity or mortality. Procedural and fluoroscopy times were not significantly different between the groups. However, total X-ray absorbed dose was significantly higher in Group I (121 ± 69 vs 29 ± 16 mGy/cm2, p < 0.01). Immediate, 24 h, and mid-term (46 ± 37 months, median 39) complete occlusion were recorded in 72.7, 90.9, and 97% of patients, respectively without significant difference between the groups. In conclusion, transcatheter closure of AD with Amplatzer Duct Occluder devices is feasible, safe, and effective also in infants less than 6 kg, without significant difference between the most commonly used devices, namely, ADO I and ADO II-AS.
Keywords: Arterial duct; Device; Low-weight infant.
Similar articles
-
Single-center experience in percutaneous closure of arterial duct with Amplatzer duct Occluder II additional sizes.Catheter Cardiovasc Interv. 2017 May;89(6):1045-1050. doi: 10.1002/ccd.26860. Epub 2016 Nov 10. Catheter Cardiovasc Interv. 2017. PMID: 27862909
-
Comparison of the results of transcatheter closure of patent ductus arteriosus with newer Amplatzer devices.Catheter Cardiovasc Interv. 2013 Aug 1;82(2):253-9. doi: 10.1002/ccd.24768. Epub 2013 Feb 21. Catheter Cardiovasc Interv. 2013. PMID: 23427043
-
Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus.Catheter Cardiovasc Interv. 2013 Nov 15;82(6):961-7. doi: 10.1002/ccd.24957. Epub 2013 Aug 9. Catheter Cardiovasc Interv. 2013. PMID: 23592558
-
[Transcatheter occlusion of patent ductus arteriosus in a preterm infant and review of literatures].Zhonghua Er Ke Za Zhi. 2016 Jan;54(1):43-6. doi: 10.3760/cma.j.issn.0578-1310.2016.01.010. Zhonghua Er Ke Za Zhi. 2016. PMID: 26791923 Review. Chinese.
-
Evolution of strategies for management of the patent arterial duct.Cardiol Young. 2007 Sep;17 Suppl 2:68-74. doi: 10.1017/S1047951107001175. Cardiol Young. 2007. PMID: 18039400 Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials