Investigating Speech Recognition and listening effort with different device configurations in adult cochlear implant users
- PMID: 29457564
- DOI: 10.1080/14670100.2018.1424513
Investigating Speech Recognition and listening effort with different device configurations in adult cochlear implant users
Abstract
Objectives: The purpose of this study was to investigate speech recognition in noise and listening effort among a group of adults with cochlear implants (CIs). Two main research questions were addressed. First, what are the effects of omni versus directional microphone configuration on speech recognition and listening effort for noisy conditions? Second, what is the effect of unilateral versus bimodal or bilateral CI listening on speech recognition and listening effort in noisy conditions?
Design: Sixteen adults (mean age 58 years) with CIs participated. Listening effort was measured using a dual-task paradigm and also using a self-reported rating of difficulty scale. In the dual-task measure, participants were asked to repeat monosyllabic words while at the same time press a button in response to a visual stimulus. Participants were tested in two baseline conditions (speech perception alone and visual task alone) and in the following experimental conditions: (1) quiet with an omnidirectional microphone, (2) noise with an omnidirectional microphone, (3) noise with a directional microphone, and (4) noise with a directional microphone and with a second sided CI or hearing aid. When present, the noise was fixed with a +5 dB signal-to-noise ratio. After each listening condition, the participants rated the degree of listening difficulty.
Results: Changing the microphone from omni to directional mode significantly enhanced speech recognition in noise performance. There were no significant changes in speech recognition between the unilateral and bimodal/bilateral CI listening conditions. Listening effort, as measured by reaction time, increased significantly between the baseline and omnidirectional quiet listening condition though did not change significantly across the remaining listening conditions. Self-perceived listening effort revealed a greater effort for the noisy conditions, and reduced effort with the move from an omni to a directional microphone.
Conclusions: Directional microphones significantly improve speech in noise recognition over omnidirectional microphones and allowed for decreased self-perceived listening effort. The dual task used in this study failed to show any differences in listening effort across the experimental conditions and may not be sensitive enough to detect changes in listening effort.
Keywords: Cochlear Implant; Directional Microphone; Listening Effort; Speech Recognition.
Similar articles
-
Combining directional microphone and single-channel noise reduction algorithms: a clinical evaluation in difficult listening conditions with cochlear implant users.Ear Hear. 2012 Jul-Aug;33(4):e13-23. doi: 10.1097/AUD.0b013e31824b9e21. Ear Hear. 2012. PMID: 22555182
-
Benefit of a commercially available cochlear implant processor with dual-microphone beamforming: a multi-center study.Otol Neurotol. 2012 Jun;33(4):553-60. doi: 10.1097/MAO.0b013e31825367a5. Otol Neurotol. 2012. PMID: 22588233 Clinical Trial.
-
A directional remote-microphone for bimodal cochlear implant recipients.Int J Audiol. 2018 Nov;57(11):858-863. doi: 10.1080/14992027.2018.1508896. Epub 2018 Sep 27. Int J Audiol. 2018. PMID: 30261771
-
Speech Understanding in Complex Listening Environments by Listeners Fit With Cochlear Implants.J Speech Lang Hear Res. 2017 Oct 17;60(10):3019-3026. doi: 10.1044/2017_JSLHR-H-17-0035. J Speech Lang Hear Res. 2017. PMID: 29049602 Free PMC article. Review.
-
[Research progress of microphone array based front-end speech enhancement technology for cochlear implant].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2019 Aug 25;36(4):696-704. doi: 10.7507/1001-5515.201805050. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2019. PMID: 31441274 Free PMC article. Review. Chinese.
Cited by
-
Dichotic listening performance and effort as a function of spectral resolution and interaural symmetry.J Acoust Soc Am. 2021 Aug;150(2):920. doi: 10.1121/10.0005653. J Acoust Soc Am. 2021. PMID: 34470337 Free PMC article.
-
Reduced digit spans and ear dominance using dichotic digits in bimodal cochlear-implant users.JASA Express Lett. 2024 May 1;4(5):054403. doi: 10.1121/10.0025977. JASA Express Lett. 2024. PMID: 38727569 Free PMC article.
-
Interaural speech asymmetry predicts bilateral speech intelligibility but not listening effort in adults with bilateral cochlear implants.Front Neurosci. 2022 Dec 7;16:1038856. doi: 10.3389/fnins.2022.1038856. eCollection 2022. Front Neurosci. 2022. PMID: 36570844 Free PMC article.
-
Counting or discriminating the number of voices to assess binaural fusion with single-sided vocoders.J Acoust Soc Am. 2020 Jan;147(1):446. doi: 10.1121/10.0000511. J Acoust Soc Am. 2020. PMID: 32006956 Free PMC article.
-
Examining Delayed Recall in Cochlear Implant Users Using the Montreal Cognitive Assessment, California Verbal Learning Test, Third Edition, and Item Specific Deficit Approach: Preliminary Results.Front Psychol. 2021 Nov 4;12:749045. doi: 10.3389/fpsyg.2021.749045. eCollection 2021. Front Psychol. 2021. PMID: 34803831 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous