Smartphone-Based Goniometry Accuracy in Clinical Scenarios
- PMID: 29461194
Smartphone-Based Goniometry Accuracy in Clinical Scenarios
Abstract
This study compared two popular iPhone-based goniometer applications to the gold standard universal goniometer for the measurement of the hip and knee joints in scenarios mimicking the normal pace of an orthopaedic clinical practice.Three physicians measured hip and knee joint angles 35 times with one of three goniometers: universal 12-inch goniometer, DrGoniometer (iPhone-5 based), and SimpleGoniometer (iPhone-5 based). Data wwere analyzed using Pearson correlation coefficient calculations. Average knee angles measured with the universal goniometer, DrGoniometer, and SimpleGoniometer measured 83.46°, 85.23°, and 80.39°, respectively. The smartphone-based goniometers had moderate agreement with the universal goniometer in the knee (r > .322). Average hip angles measured with the universal goniometer, DrGoniometer, and SimpleGoniometer measured 62.34°, 60.87°, and 59.34°, respectively. The smartphone-based goniometers had moderate agreement with the universal goniometer in the hip (r > .168). Smartphone-based goniometers gave accurate, with weak to moderate correlation, measurements for the knee and hip. (Journal of Surgical Orthopaedic Advances 26(4):223-226, 2017).
Similar articles
-
Reliability and concurrent validity of knee angle measurement: smart phone app versus universal goniometer used by experienced and novice clinicians.Man Ther. 2014 Dec;19(6):569-74. doi: 10.1016/j.math.2014.05.009. Epub 2014 Jun 4. Man Ther. 2014. PMID: 24942491
-
Evaluation of knee range of motion: Correlation between measurements using a universal goniometer and a smartphone goniometric application.J Bodyw Mov Ther. 2017 Jul;21(3):699-703. doi: 10.1016/j.jbmt.2016.11.008. Epub 2016 Nov 17. J Bodyw Mov Ther. 2017. PMID: 28750987
-
Assessment of novel digital and smartphone goniometers for measurement of canine stifle joint angles.Am J Vet Res. 2016 Jul;77(7):749-55. doi: 10.2460/ajvr.77.7.749. Am J Vet Res. 2016. PMID: 27347828
-
The validity and reliability of DrGoniometer, a smartphone application, for measuring forearm supination.J Hand Ther. 2019 Jan-Mar;32(1):110-117. doi: 10.1016/j.jht.2018.03.003. Epub 2018 Jul 17. J Hand Ther. 2019. PMID: 30025841
-
Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects.Physiother Res Int. 1997;2(3):150-66. doi: 10.1002/pri.97. Physiother Res Int. 1997. PMID: 9421820 Review.
MeSH terms
LinkOut - more resources
Full Text Sources