. 2018 Jun;37(5):1809-1814.
doi: 10.1002/nau.23529. Epub 2018 Feb 21.

The female continence mechanism measured by high resolution manometry: Urethral bulking versus midurethral sling

Affiliations

The female continence mechanism measured by high resolution manometry: Urethral bulking versus midurethral sling

Erika J Wasenda et al. Neurourol Urodyn. 2018 Jun.

Abstract

Aims: Traditional technology to characterize urethral pressure changes during dynamic conditions is limited by slow response times or artifact-inducing withdrawal maneuvers. The 8F high-resolution manometry (HRM) catheter (ManoScan™ ESO, Covidien) has advantages of fast response times and the ability to measure urethral pressures along the urethral length without withdrawal. Our objective was to determine static and dynamic maximum urethral closure pressures (MUCPs) and resting functional urethral length (FUL) in women using HRM before and after transurethral bulking and compare results to other women who underwent midurethral sling (MUS).

Methods: We recorded rest, cough, and strain MUCPs and FUL in 24 women before and after transurethral bulking with polydimethylsiloxane (Macroplastique®) using the HRM catheter and compared these changes to HRM values from 26 women who had the same measures before and after MUS.

Results: At rest, MUCPs increased minimally after both urethral bulking and MUS (3 vs 0.4 cm H2 O respectively, P = 0.4). Under dynamic conditions there were statistically insignificant small increases in MUCP and these increases were markedly less than after MUS (cough: 1.5 vs 63.8 cm H2 O, P < 0.001 and strain: 11.5 vs 57.7 cm H2 O, P < 0.001). FUL increased by 0.5 cm after transurethral bulking (P = 0.003), and decreased by 0.25 cm after MUS placement (P = 0.012).

Conclusions: The mechanism of continence after urethral bulking differs from MUS. While MUS increases dynamic MUCP, bulking may rely on increasing the length of the continence zone.

Keywords: functional urethral length; high resolution manometry; maximum urethral closures pressures; midurethral sling; stress urinary incontinence; urethral bulking.

PubMed Disclaimer

Figures

FIGURE 1
FIGURE 1
High resolution manometry catheter. Diameter 2.75 mm with 4-mm copper pressure sensorsspaced 3 mm apart. Each sensor has 16 circumferential pressure-sensing foci (inset)

Comment in

References

    1. Wu J, Matthews C, Conover M, Pate V, Jonsson Funk M. Lifetime risk of stress incontinence or pelvic organ prolapse surgery. Obstet Gynecol. 2014;123:1201–1206. - PMC - PubMed
    1. Kirby A, Tan-Kim J, Nager C. Dynamic maximum urethral closure pressures measured by high resolution manometry increase markedly after sling surgery. Int Urogynecol J. 2015;26:905–909. - PMC - PubMed
    1. Kerr L. Bulking agents in the treatment of stress urinary incontinence: history, outcomes, patient populations, and reimbursement profile. Rev Urol. 2005;7:S3–S11. - PMC - PubMed
    1. Matsuoka PK, Locali RF, Pacetta AM, Chada Baracat E, Milhem Haddad J. The efficacy and safety of urethral injection therapy for urinary incontinence in women: a systematic review. Clinics. 2016;71:94–100. - PMC - PubMed
    1. Tan-Kim J, Weinstein MM, Nager CW. Urethral sleeve sensor: a non-withdrawal method to measure maximum urethral pressure. Int Urogynecol J. 2010;21:685–691. - PMC - PubMed

Publication types

LinkOut - more resources