Preanalytics of urine sediment examination: effect of relative centrifugal force, tube type, volume of sample and supernatant removal
- PMID: 29472802
- PMCID: PMC5806615
- DOI: 10.11613/BM.2018.010707
Preanalytics of urine sediment examination: effect of relative centrifugal force, tube type, volume of sample and supernatant removal
Abstract
Introduction: Laboratories often modify procedures recommended by the European Urinalysis Guidelines for urine sediment analysis. The aim of this study was to compare the recommended protocol with our routine laboratory procedure and to evaluate the possible impact of modifications in the relative centrifugal force, type of tube, method of supernatant aspiration and urine volume on patient's results.
Material and methods: Firstly, relative centrifugal force was investigated using 20 pairs of samples examined after centrifugation at 400xg and 1358xg. In phase two, 110 samples were examined, paired as: round bottom vs conical tube (N = 46), decanting vs suction of supernatant (N = 100) and 10 mL vs 5 mL of urine sample (N = 101).
Results: The number of erythrocytes, leukocytes and squamous epithelial cells was significantly lower after centrifugation at 400xg (P = 0.001, 0.002 and 0.004, respectively). The number of leukocytes was significantly lower in conical tubes (P = 0.010), after the suction of supernatant (P = 0.045) and in 5 mL urine (P < 0.001). The number of squamous epithelial cells was significantly lower after the suction of supernatant (P < 0.001) and in 5 mL urine (P < 0.001). The number of erythrocytes (P < 0.001), total non-hyaline casts (P < 0.001) and the frequency of granular casts (P = 0.039) was significantly lower in 5 mL urine.
Conclusion: Lower results of leukocytes, erythrocytes, squamous cells and non-hyaline casts were recorded in recommended procedures (centrifugation at 400xg, suction of supernatant, conical tube, 5 mL of sample) than in routine procedure (centrifugation at 1358xg, decanting of supernatant, round bottom tube, 10 mL) used in our laboratory.
Keywords: laboratory error; preanalytical phase; urinalysis; urine sediment.
Conflict of interest statement
Potential conflict of interest: None declared.
Figures

Similar articles
-
UriSed - Preliminary reference intervals and optimal method for urine sediment analysis in newborns and infants.Clin Biochem. 2016 Aug;49(12):909-14. doi: 10.1016/j.clinbiochem.2016.04.013. Epub 2016 Apr 28. Clin Biochem. 2016. PMID: 27132496
-
Quantitative analysis of urine sediment using newly designed centrifuge tubes.Ann Clin Lab Sci. 2002 Winter;32(1):55-60. Ann Clin Lab Sci. 2002. PMID: 11848619
-
Comparison and interpretation of urinalysis performed by a nephrologist versus a hospital-based clinical laboratory.Am J Kidney Dis. 2005 Nov;46(5):820-9. doi: 10.1053/j.ajkd.2005.07.039. Am J Kidney Dis. 2005. PMID: 16253721 Clinical Trial.
-
[How Far We can Diagnose by Urine Sediment Tests?].Rinsho Byori. 2014 Nov;62(11):1098-101. Rinsho Byori. 2014. PMID: 27509728 Review. Japanese.
-
Preanalytics in urinalysis.Clin Biochem. 2016 Dec;49(18):1346-1350. doi: 10.1016/j.clinbiochem.2016.10.016. Epub 2016 Oct 23. Clin Biochem. 2016. PMID: 27784640 Review.
Cited by
-
Diagnostic value of urinary microprotein concentration for patients with negative urinary protein test results and positive urinary casts on microscopic examination.J Clin Lab Anal. 2020 Nov;34(11):e23487. doi: 10.1002/jcla.23487. Epub 2020 Jul 19. J Clin Lab Anal. 2020. PMID: 32686106 Free PMC article.
-
Urinary extracellular vesicles: A position paper by the Urine Task Force of the International Society for Extracellular Vesicles.J Extracell Vesicles. 2021 May;10(7):e12093. doi: 10.1002/jev2.12093. Epub 2021 May 21. J Extracell Vesicles. 2021. PMID: 34035881 Free PMC article.
-
Impact of chemical preservative in urine samples.EJIFCC. 2020 Mar 20;31(1):56-64. eCollection 2020 Mar. EJIFCC. 2020. PMID: 32256289 Free PMC article.
-
Automated urine analyzers: a comparative study of Atellica UAS 800 and UAS 60 with risk analysis.Biochem Med (Zagreb). 2025 Feb 15;35(1):010707. doi: 10.11613/BM.2025.010707. Biochem Med (Zagreb). 2025. PMID: 39974193 Free PMC article.
-
Consistency analysis of the Sysmex UF-5000 and Atellica UAS 800 urine sedimentation analyzers.J Clin Lab Anal. 2022 Sep;36(9):e24659. doi: 10.1002/jcla.24659. Epub 2022 Aug 16. J Clin Lab Anal. 2022. PMID: 35971777 Free PMC article.
References
-
- European Confederation of Laboratory Medicine European urinalysis guidelines. Scand J Clin Lab Invest Suppl. 2000;231:1–86. - PubMed
-
- Simerville JA, Maxted WC, Pahira JJ. Urinalysis: a comprehensive review. Am Fam Physician. 2005;71:1153–62. - PubMed
-
- Cameron JS. A history of urine microscopy. Clin Chem Lab Med. 2015;53 Suppl 2:s1453–64. - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous