Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2018 Sep;16(3):130-138.
doi: 10.1007/s12574-018-0374-8. Epub 2018 Feb 23.

The mystery of defining aortic valve area: what have we learnt from three-dimensional imaging modalities?

Affiliations
Review

The mystery of defining aortic valve area: what have we learnt from three-dimensional imaging modalities?

Ebraham Alskaf et al. J Echocardiogr. 2018 Sep.

Abstract

Aortic valve area is one of the main criteria used by echocardiography to determine the degree of valvular aortic stenosis, and it is calculated using the continuity equation which assumes that the flow volume of blood is equal at two points, the aortic valve area and the left ventricular outflow tract (LVOT). The main fallacy of this equation is the assumption that the LVOT area which is used to calculate the flow volume at the LVOT level is circular, where it is often an ellipse and sometimes irregular. The aim of this review is to explain the physiology of the continuity equation, the different sources of errors, the added benefits of using three-dimensional imaging modalities to measure LVOT area, the latest recommendations related to valvular aortic stenosis, and to introduce future perspectives. A literature review of studies comparing aortic valve area and LVOT area, after using three-dimensional data, has shown underestimation of both measurements when using the continuity equation. This has more impact on patients with discordant echocardiographic measurements when aortic valve area is disproportionate to haemodynamic measurements in assessing the degree of aortic stenosis. Although fusion imaging modalities of LVOT area can help in certain group of patients to address the issue of aortic valve area underestimation, further research on introducing a correction factor to the conventional continuity equation might be more rewarding, saving patients additional tests and potential radiation, with no clear evidence of cost-effectiveness.

Keywords: Aortic valve area; Cardiac computed tomography angiography; Continuity equation; Correction factor; Echocardiography; Left ventricular outflow tract.

PubMed Disclaimer

References

    1. Am J Cardiol. 2012 Jun 1;109(11):1626-31 - PubMed
    1. J Am Soc Echocardiogr. 2017 Apr;30(4):372-392 - PubMed
    1. J Cardiovasc Comput Tomogr. 2014 Jan-Feb;8(1):52-7 - PubMed
    1. Circulation. 2003 Jul 22;108(3):319-24 - PubMed
    1. Circulation. 1986 Mar;73(3):452-9 - PubMed

LinkOut - more resources