Ultralow Dose MSCT Imaging in Dental Implantology

Affiliations
Review

Ultralow Dose MSCT Imaging in Dental Implantology

Gerlig Widmann et al. Open Dent J. .

Abstract

Introduction: The Council Directive 2013/59 Euratom has a clear commitment for keeping medical radiation exposure as low as reasonably achievable and demands a regular review and use of diagnostic reference levels.

Methods: In dental implantology, the range of effective doses for cone beam computed tomography (CBCT) shows a broad overlap with multislice computed tomography (MSCT). More recently, ultralow dose imaging with new generations of MSCT scanners may impart radiation doses equal to or lower than CBCT. Dose reductions in MSCT have been further facilitated by the introduction of iterative image reconstruction technology (IRT), which provides substantial noise reduction over the current standard of filtered backward projection (FBP).

Aim: The aim of this article is to review the available literature on ultralow dose CT imaging and IRTs in dental implantology imaging and to summarize their influence on spatial and contrast resolution, image noise, tissue density measurements, and validity of linear measurements of the jaws.

Conclusion: Application of ultralow dose MSCT with IRT technology in dental implantology offers the potential for very large dose reductions compared with standard dose imaging. Yet, evaluation of various diagnostic tasks related to dental implantology is still needed to confirm the results obtained with various IRTs and ultra-low doses so far.

Keywords: Cone beam computed tomography; Dental Implantology; Filtered backward projection; Multislice computed tomography; Radiation dose; Ultralow dose.

PubMed Disclaimer

References

    1. Tyndall D.A., Price J.B., Tetradis S., Ganz S.D., Hildebolt C., Scarfe W.C. Position statement of the American academy of oral and maxillofacial radiology on selection criteria for the use of radiology in dental implantology with emphasis on cone beam computed tomography. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. 2012;113(6):817–826. doi: 10.1016/j.oooo.2012.03.005. - DOI - PubMed
    1. Harris D., Horner K., Gröndahl K., Jacobs R., Helmrot E., Benic G.I., Bornstein M.M., Dawood A., Quirynen M. E.A.O. guidelines for the use of diagnostic imaging in implant dentistry 2011. A consensus workshop organized by the European Association for Osseointegration at the Medical University of Warsaw. Clin. Oral Implants Res. 2012;23(11):1243–1253. doi: 10.1111/j.1600-0501.2012.02441.x. - DOI - PubMed
    1. European Commission. Radiation Protection No. 172. Cone beam CT for dental and maxillofacial radiology (Evidence-based guidelines). Directorate General for Energy Directorate D–Nuclear Energy unit D4–Radiation Protection. 2012.
    1. United Nations Scientific Committee on the Effects of Atomic Radiation, Sources and effects of ionizing radiation. Official Records of the General Assembly, Sixty-third Session, Supplement No 46. New York: United Nations; 2008.
    1. Kalra M.K., Sodickson A.D., Mayo-Smith W.W. CT radiation: Key concepts for gentle and wise use. Radiographics. 2015;35(6):1706–1721. doi: 10.1148/rg.2015150118. - DOI - PubMed

LinkOut - more resources