. 2018 Jul;34(7):1127-1133.
doi: 10.1007/s10554-018-1322-4. Epub 2018 Feb 28.

Left and right ventricular parameters corrected with threshold-based quantification method in a normal cohort analyzed by three independent observers with various training-degree

Affiliations

Left and right ventricular parameters corrected with threshold-based quantification method in a normal cohort analyzed by three independent observers with various training-degree

Ibolya Csecs et al. Int J Cardiovasc Imaging. 2018 Jul.

Abstract

While cardiac magnetic resonance (CMR) is the reference method to evaluate left and right ventricular functions, volumes and masses, there is no widely accepted method for the quantitative analysis of trabeculae and papillary muscles (TPM). The aim of this study was to investigate the effect of TPM quantification on left and right ventricular CMR values in a normal cohort and to investigate interobserver variability of threshold-based (TB) analysis by three independent observers with variant experience in CMR. At our clinic, 60 healthy volunteers (30 males, mean age 25.6 ± 4.7 years) underwent CMR scan performed on a 1.5T Philips Achieva MR machine. On short-axis cine images, endo- and epicardial contours were detected by three independent observers with variable experience in CMR (low- ca. 120, mid- > 800, high-experienced > 5000 original CMR cases). Using Conv and TB methods (Medis 7.6 QMass software Leiden, The Netherland), we measured LV and RV ejection fractions, end-diastolic, end-systolic, stroke volumes and masses. We used TB method for quantifying TPM in ventricles using epicardial contour layers. Interobserver variability was evaluated, and the observer's experience as an impact on variability of each investigated parameters was assessed. Comparing Conv and TB quantification methods' significant difference were detected for all LV and RV parameters in case of all observers (H, M and L p < 0.0001). The global intraclass correlation coefficient (G-ICC) representing interobserver agreement for all investigated parameters was lower with Conv method (G-ICCConv vs. G-ICCTB 0.86 vs. 0.92 p < 0.0001). The ICC of LV parameters was higher using TB quantification (LV-ICCConv vs. LV-ICCTB 0.92 vs. 0.96 p < 0.0001), and for the evaluation of RV values, the TB method also had significantly higher interobserver agreement (RV-ICCConv vs. RV-ICCTB 0.80 vs. 0.89 p < 0.0001). The TB algorithm could be a consistent method to assess LV and RV CMR values, and to measure trabeculae and papillary muscles quantitatively in various level of experience in CMR.

Keywords: Automated thresholding; Cardiac chamber quantification; Cardiac magnetic resonance; Endocardium; Papillary muscles; Trabeculae.

PubMed Disclaimer

References

    1. JACC Cardiovasc Imaging. 2012 Nov;5(11):1115-23 - PubMed
    1. J Cardiovasc Magn Reson. 2004;6(1):9-16 - PubMed
    1. Eur Radiol. 2016 May;26(5):1503-11 - PubMed
    1. Am J Cardiol. 2005 Jan 15;95(2):199-203 - PubMed
    1. Int J Cardiovasc Imaging. 2014 Mar;30(3):599-608 - PubMed

LinkOut - more resources