Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Mar;6(3):E259-E265.
doi: 10.1055/s-0043-125362. Epub 2018 Feb 28.

Multicenter experience from the UK and Ireland of use of lumen-apposing metal stent for transluminal drainage of pancreatic fluid collections

Affiliations

Multicenter experience from the UK and Ireland of use of lumen-apposing metal stent for transluminal drainage of pancreatic fluid collections

Suresh Vasan Venkatachalapathy et al. Endosc Int Open. 2018 Mar.

Abstract

Background and study aims: Pancreatic fluid collection (PFC) is a common complication of pancreatitis for which endoscopic ultrasound-guided drainage is first-line treatment. A new single-device, lumen-apposing, covered self-expanding metal stent (LAMS) has been licensed for PFC drainage. We therefore present our multicenter experience with the LAMS for PFC drainage in a multicenter prospective case series to assess success and complication rates.

Patients and methods: All adult patients from 11 tertiary centers who had LAMS placement for PFC from July 2015 to July 2016 were included. Data including indications, technical success, clinical success, collection resolution, stent removal, early and late adverse events (AEs), mortality and recurrence at 6 months were collected.

Results: 116 patients, median age 52.5 years (range 16 - 80) and 67 % male, were treated with a single LAMS in each case. The indication was walled off necrosis (WON) in 70 and pseudocyst in 46. Median size of the PFC was 11 cm (5 - 21 cm) and the estimated median necrotic volume in WON was 30 % (5 % - 90 %). Stent insertion was technically successful in 115 (99.1 %) and clinically successful in 109 (94 %). Early serious AEs (SAEs): n = 7 sepsis, n = 1 stent blockage with food, n = 1 stent migration requiring laparotomy, n = 1 stent dislodgement and n = 1 bleeding requiring emboliZation. Late AEs: n = 1 buried stent and n = 1 esophageal fistula. Non-procedure-related deaths: n = 3 (2.5 %).

Conclusion: This multicenter case series demonstrates that use of the new LAMS is feasible, effective and relatively safe in draining PFC with a technical success rate of 99 % and cumulative SAE rate of 11.2 %.

PubMed Disclaimer

Conflict of interest statement

Competing interests None

Figures

Fig. 1
Fig. 1
Lumen apposing metal stent (LAMS).
Fig. 2
Fig. 2
Partially deployed LAMS.

References

    1. Banks P A, Bollen T L, Dervenis C et al.Classification of acute pancreatitis – 2012: revision of the Atlanta classification and definitions by international consensus. Gut. 2013;62:102–111. - PubMed
    1. Kahaleh M, 1, Shami V M, Conaway M R et al.Endoscopic ultrasound drainage of pancreatic pseudocyst: a prospective comparison with conventional endoscopic drainage. Endoscopy. 2006 Apr;38:355–359. - PubMed
    1. Binmoeller K F, Seifert H, Walter A et al.Transpapillary and transmural drainage of pancreatic pseudocysts. Gastrointest Endosc. 1995;42:219–224. - PubMed
    1. Varadarajulu S, Rana S S, Bhasin D K. Endoscopic therapy for pancreatic duct leaks and disruptions. Gastrointest Endosc Clin N Am. 2013;23:863–892. - PubMed
    1. Singhal S, Rotman S R, Gaidhane M et al.Pancreatic fluid collection drainage by endoscopic ultrasound: an update. Clin Endosc. 2013;46:506–514. - PMC - PubMed

LinkOut - more resources