Renal and extrarenal handling of a new imaging compound (99m-Tc-MAG-3) in the rat
- PMID: 2949975
- DOI: 10.1007/BF00254747
Renal and extrarenal handling of a new imaging compound (99m-Tc-MAG-3) in the rat
Abstract
We investigated the renal clearance, the extrarenal clearance, the biodistribution, the plasma extraction ratio and the imaging quality on a scintillation camera of a new substance: 99mTc-mercaptoacetyltriglycine (MAG-3) in rats. Simultaneously 125I-hippurate (OIH) and 51Cr-EDTA were used as reference substances. In scintillation camera studies, 123I-hippurate served as reference. MAG-3 was prepared by kit labelling without further purification, as it would be used in clinical studies. However in three separate rats, HPLC purified MAG-3 was used. High renal clearance and extraction ratio was found but these were less than that for OIH (1.95 ml/min per 100 g BW vs 2.76 ml/min per 100 g BW and 64% vs 85% respectively). The extrarenal clearance was higher for MAG-3 than for OIH (0.20 ml/min per 100 g BW vs 0.04 ml/min per 100 g BW), presumably because of bile excretion. HPLC purification increased the renal excretion of MAG-3: the clearance was 2.53 ml/min per 100 g BW, the extraction fraction 75%, but the extrarenal clearance was unchanged. The imaging quality was comparable to that of 123I-hippurate in early pictures, but extrarenal activity, presumably representing bile, was observed in late pictures. We conclude that MAG-3 has some potential for the replacement of OIH but clinical studies are necessary to test whether the same conditions and limitations exist in humans.
Similar articles
-
Renal and extrarenal clearance of 99mTc-MAG3: a comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular filtration rate.Eur J Nucl Med. 1995 Dec;22(12):1379-84. doi: 10.1007/BF01791145. Eur J Nucl Med. 1995. PMID: 8586082
-
Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats.J Nucl Med. 1987 Dec;28(12):1881-7. J Nucl Med. 1987. PMID: 2960790
-
Glomerular filtration and tubular secretion of MAG-3 in the rat kidney.J Nucl Med. 1989 Dec;30(12):1986-91. J Nucl Med. 1989. PMID: 2531220
-
Technetium-99m MAG-3 clearances after captopril in experimental renovascular hypertension.J Nucl Med. 1989 May;30(5):666-71. J Nucl Med. 1989. PMID: 2523959
-
Clinical comparison of I-131 orthoiodohippurate and the kit formulation of Tc-99m mercaptoacetyltriglycine.Radiology. 1989 Mar;170(3 Pt 1):721-5. doi: 10.1148/radiology.170.3.2521734. Radiology. 1989. PMID: 2521734
Cited by
-
Dynamic renal scanning using 99mTc-MAG-3 in man.Eur J Nucl Med. 1989;15(10):635-40. doi: 10.1007/BF00251675. Eur J Nucl Med. 1989. PMID: 2530091
-
Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample.Eur J Nucl Med. 1991;18(1):28-31. doi: 10.1007/BF00177681. Eur J Nucl Med. 1991. PMID: 1826882
-
Preclinical evaluation of 99mTc(CO)3-aspartic-N-monoacetic acid, a renal radiotracer with pharmacokinetic properties comparable to 131I-o-iodohippurate.J Nucl Med. 2012 Aug;53(8):1277-83. doi: 10.2967/jnumed.111.102236. Epub 2012 Jun 20. J Nucl Med. 2012. PMID: 22717977 Free PMC article.
-
Technetium 99m mercaptoacetyltriglycine gamma camera clearance calculations: methodological problems.Eur J Nucl Med. 1991;18(2):83-6. doi: 10.1007/BF00950751. Eur J Nucl Med. 1991. PMID: 1828421
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Research Materials