Higher prevalence of periprosthetic fractures with ceramic on polyethylene hip bearing compared with ceramic on ceramic on the contralateral side: a forty year experience with hip osteonecrosis
- PMID: 29504054
- DOI: 10.1007/s00264-018-3863-5
Higher prevalence of periprosthetic fractures with ceramic on polyethylene hip bearing compared with ceramic on ceramic on the contralateral side: a forty year experience with hip osteonecrosis
Abstract
Purpose: It is unclear whether late THA periprosthetic femoral fractures are related to a mechanical mechanism that decreases strength of the femur (for example, loosening) or to a biological problem as osteolysis. It is also unknown if ceramic on ceramic bearing couples decrease the risk of late periprosthetic fractures as a result of the absence of wear and osteolysis.
Material and methods: We therefore asked whether the cumulative long-term fractures were different according to the couple of friction ceramic on ceramic or ceramic on polyethylene in 327 patients (654 hips) with bilateral THA (one ceramic-ceramic, and the contralateral ceramic-polyethylene) who had THA with cemented stems performed between from 1978 to 2000 for osteonecrosis.
Results: There were two intra-operative fractures (0.3%). The median follow-up was 22 years (range, 15-40 years), and at the most recent follow-up, the cumulative number of late (after 7 years of follow-up) post-operative fractures was 32 (5% of 654 hips). Fractures were unilateral, which means for the 327 patients, a 10% rate of fractures. Periprosthetic fractures increased in number with follow-up: seven fractures (1% of 654 hips) occurred within ten years of THA implantation, 20 (3%) within 20 years, 26 (4%) within 30 years, and 32 (5%) within 40 years. The risk of fracture was influenced (p < 0.001) by the bearing surfaces at the time of prosthetic implantation, low (0.3%) for ceramic on ceramic (1/32 fractures; 1/327 hips), high (10%) for ceramic on PE (31/32 fractures; 31/327 hips).
Conclusion: In summary, when the contralateral hip of the same patient is the control, after 40 years of follow-up, post-operative fractures occur 30 times more often on the side with PE cup than on the side with ceramic/ceramic bearing.
Keywords: Bearing surface; Ceramic on ceramic; Ceramic on polyethylene; Hip friction; Hip osteonecrosis; Periprosthetic fracture.
Similar articles
-
Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors.Clin Orthop Relat Res. 2015 Dec;473(12):3762-9. doi: 10.1007/s11999-015-4378-7. Clin Orthop Relat Res. 2015. PMID: 26054482 Free PMC article.
-
Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?Clin Orthop Relat Res. 2016 Oct;474(10):2190-9. doi: 10.1007/s11999-016-4917-x. Clin Orthop Relat Res. 2016. PMID: 27255729 Free PMC article.
-
High Risk of Neck-liner Impingement and Notching Observed with Thick Femoral Neck Implants in Ceramic-on-ceramic THA.Clin Orthop Relat Res. 2022 Apr 1;480(4):690-699. doi: 10.1097/CORR.0000000000002022. Clin Orthop Relat Res. 2022. PMID: 34699410 Free PMC article.
-
Comparative postoperative prognosis of ceramic-on-ceramic and ceramic-on-polyethylene for total hip arthroplasty: an updated systematic review and meta-analysis.PeerJ. 2024 Sep 25;12:e18139. doi: 10.7717/peerj.18139. eCollection 2024. PeerJ. 2024. PMID: 39346065 Free PMC article.
-
Undetected Intraoperative Periprosthetic Femoral Fractures in Patients Undergoing Primary Total Hip Arthroplasty: A Retrospective Case Series and Literature Review.Orthop Surg. 2023 Mar;15(3):758-765. doi: 10.1111/os.13646. Epub 2023 Jan 17. Orthop Surg. 2023. PMID: 36647808 Free PMC article. Review.
Cited by
-
Stem cell therapy in bilateral osteonecrosis: computer-assisted surgery versus conventional fluoroscopic technique on the contralateral side.Int Orthop. 2018 Jul;42(7):1593-1598. doi: 10.1007/s00264-018-3953-4. Epub 2018 Apr 26. Int Orthop. 2018. PMID: 29696307 Clinical Trial.
-
Total hip arthroplasty for sickle cell osteonecrosis: guidelines for perioperative management.EFORT Open Rev. 2020 Oct 26;5(10):641-651. doi: 10.1302/2058-5241.5.190073. eCollection 2020 Oct. EFORT Open Rev. 2020. PMID: 33204507 Free PMC article. Review.
-
The impact of polyethylene abrasion on the occurrence of periprosthetic proximal femoral fractures in patients with total hip arthroplasty.Eur J Trauma Emerg Surg. 2021 Feb;47(1):211-216. doi: 10.1007/s00068-019-01222-1. Epub 2019 Sep 13. Eur J Trauma Emerg Surg. 2021. PMID: 31520158
-
Hip osteonecrosis: stem cells for life or behead and arthroplasty?Int Orthop. 2018 Jul;42(7):1425-1428. doi: 10.1007/s00264-018-4026-4. Epub 2018 Jun 8. Int Orthop. 2018. PMID: 29934715 No abstract available.
-
Revision in Ceramic-on-Ceramic and Ceramic-on-Polyethylene Bearing in Primary Total Hip Arthroplasty with Press-fit Cups: A Systematic Review and Meta-analysis of Different Methodological Study Designs.Arch Bone Jt Surg. 2022 Nov;10(11):916-936. doi: 10.22038/ABJS.2022.59354.2933. Arch Bone Jt Surg. 2022. PMID: 36561219 Free PMC article. Review.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical