Radiation doses were measured for the first time in intraoral and panoramic dental radiology at Sudanese hospitals. Doses were determined using various exposure settings for adults and children in 8 intraoral and 6 panoramic X-ray devices. The study sample was equally divided between devices using a digital image receptor (DR) and those using conventional screen film (SF). Radiation doses are reported in terms of incident air kerma (IAK) (intraoral radiology) and kerma area product (PKA) (panoramic radiology). IAK values in intraoral radiology were: 1.45 mGy (DR), 4.45 mGy (SF), and 3.01 mGy (combined). For panoramic radiology, PKA values ranged: from 35.8 to 103.2 mGy cm2 (average: 70.4 mGy cm2) for children and from 65.7 to 151.4 mGy cm2 (average: 103.4 mGy cm2) for adults. The results showed that the downward trend in patient doses can be achieved using digital imaging. The study revealed important concerns surrounding radiation protection, such as the lack of regular quality assurance programs and the use of circular collimators.
Keywords: Intraoral radiology; Panoramic radiology; Radiation dosimetry; Radiation protection in dental radiology.
Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Measurement of radiation dose in dental radiology.Radiat Prot Dosimetry. 2005;114(1-3):168-71. doi: 10.1093/rpd/nch502. Radiat Prot Dosimetry. 2005. PMID: 15933101
-
Panoramic radiography in dental diagnostics.Swed Dent J Suppl. 1996;119:1-26. Swed Dent J Suppl. 1996. PMID: 8971997 Review.
-
Dose area product reference levels in dental panoramic radiology.Radiat Prot Dosimetry. 2004;111(3):283-7. doi: 10.1093/rpd/nch341. Epub 2004 Jul 20. Radiat Prot Dosimetry. 2004. PMID: 15266083
-
Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose-area product values.Radiat Prot Dosimetry. 2008;131(3):365-73. doi: 10.1093/rpd/ncn172. Epub 2008 Jun 11. Radiat Prot Dosimetry. 2008. PMID: 18550517
-
Review article: radiation protection in dental radiology.Br J Radiol. 1994 Nov;67(803):1041-9. doi: 10.1259/0007-1285-67-803-1041. Br J Radiol. 1994. PMID: 7820393 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources