Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2018 Apr;49(4):753-765.
doi: 10.1016/j.injury.2018.02.017. Epub 2018 Feb 21.

Surgical fixation of midshaft clavicle fractures: A systematic review of biomechanical studies

Affiliations
Comparative Study

Surgical fixation of midshaft clavicle fractures: A systematic review of biomechanical studies

Martijn H Hulsmans et al. Injury. 2018 Apr.

Abstract

Purpose: Surgical treatment of displaced midshaft clavicle fractures requires a decision between plate fixation and intramedullary (IM) fixation. Numerous studies report on the biomechanical properties of various repair constructs. The goal of this systematic review was to provide an overview of studies describing the biomechanical properties of the most commonly used surgical fixations of midshaft clavicle fractures. Additionally, we aimed to translate these biomechanical results into clinically relevant conclusions.

Methods: A computer-aided search of the EMBASE and PudMed/MEDLINE databases was conducted. Studies included for review compared biomechanical properties of plate fixation with IM fixation and superiorly positioned plates with anteroinferiorly positioned plates for midshaft clavicle fractures.

Results: Fifteen studies were eligible for inclusion. Plate fixation seemed to form a more robust construct than IM fixation in terms of stiffness and failure loading. The remaining clavicle was stronger after removal of the IM device than after removal of the plate. Superior plating of transverse fractures generally seemed to provide greater stiffness and strength during bending loads than anteroinferior plating did. The absence of cortical alignment in wedge and comminuted fractures directly influenced the fixation stability for both IM fixation and plate fixation, regardless of location.

Conclusion: Each type of fracture fixation has biomechanical advantages and disadvantages. However, exact thresholds of stiffness for inducing healing and failure strength to withstand refractures are unknown. The clinical relevance of the biomechanical studies may be arguable. Since none of the studies investigate the effect of tissue adaptation over time they should be interpreted with caution.

Keywords: Biomechanical; Biomechanics; Clavicle fracture; Clinical relevance; Failure; Intramedullary; Pin; Plate fixation; Stiffness; Superior.