Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2018 Feb;57(1):127-131.
doi: 10.1016/j.transci.2018.02.021. Epub 2018 Feb 21.

0.9% NaCl (Normal Saline) - Perhaps not so normal after all?

Affiliations
Review

0.9% NaCl (Normal Saline) - Perhaps not so normal after all?

Neil Blumberg et al. Transfus Apher Sci. 2018 Feb.

Abstract

Crystalloid infusion is widely employed in patient care for volume replacement and resuscitation. In the United States the crystalloid of choice is often normal saline. Surgeons and anesthesiologists have long preferred buffered solutions such as Ringer's Lactate and Plasma-Lyte A. Normal saline is the solution most widely employed in medical and pediatric care, as well as in hematology and transfusion medicine. However, there is growing concern that normal saline is more toxic than balanced, buffered crystalloids such as Plasma-Lyte and Lactated Ringer's. Normal saline is the only solution recommended for red cell washing, administration and salvage in the USA, but Plasma-Lyte A is also FDA approved for these purposes. Lactated Ringer's has been traditionally avoided in these applications due to concerns over clotting, but existing research suggests this is not likely a problem. In animal models and clinical studies in various settings, normal saline can cause metabolic acidosis, vascular and renal function changes, as well as abdominal pain in comparison with balanced crystalloids. The one extant randomized trial suggests that in very small volumes (2 l or less) normal saline is not more toxic than other crystalloids. Recent evidence suggests that normal saline causes substantially more in vitro hemolysis than Plasma-Lyte A and similar solutions during short term storage (24 hours) after washing or intraoperative salvage. There are now abundant data to raise concerns as to whether normal saline is the safest replacement solution in infusion therapy, red cell washing and salvage, apheresis and similar uses. In the USA, Plasma-Lyte A is also FDA approved for use with blood components and is likely a safer solution for these purposes. Its only disadvantage is a higher cost. Additional studies of the safety of normal saline for virtually all current clinical uses are needed. It seems likely that normal saline will eventually be abandoned in favor of safer, more physiologic crystalloid solutions in the coming years.

Keywords: Crystalloid; Hemolysis; Resuscitation; Saline; Transfusion.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest statement: Dr. Blumberg has served in the distant past as a consultant to and research grant recipient from manufacturers of leukoreduction filters (Terumo, Fenwal), red cell rejuvenation solutions (Biomet/Citra Labs) and cell washing devices (Terumo BCT) (Haemonetics), as well as a consultant to Alexion. Drs. Blumberg and Refaai have received consulting fees for medical services to CSL Behring. Drs. Blumberg and Spinelli have received research grant support from Philip Morris. None of the authors have received support from manufacturers of crystalloid infusion solutions.

References

    1. Myburgh JA, Mythen MG. Resuscitation fluids. N Engl J Med. 2013;369:1243–51. - PubMed
    1. Lobo DN. Intravenous 0.9% saline and general surgical patients: a problem, not a solution. Ann Surg. 2012;255:830–2. - PubMed
    1. Hahn RG. Should anaesthetists stop infusing isotonic saline? Br J Anaesth. 2014;112:4–6. - PubMed
    1. Cull DL, Lally KP, Murphy KD. Compatibility of packed erythrocytes and Ringer’s lactate solution. Surg Gynecol Obstet. 1991;173:9–12. - PubMed
    1. Lorenzo M, Davis JW, Negin S, Kaups K, Parks S, Brubaker D, et al. Can Ringer’s lactate be used safely with blood transfusions? Am J Surg. 1998;175:308–10. - PubMed