Reproducibility of acquiring ultrasonographic infant hip images by the Graf method after an infant hip ultrasound training course
- PMID: 29524009
- DOI: 10.1007/s10396-018-0876-z
Reproducibility of acquiring ultrasonographic infant hip images by the Graf method after an infant hip ultrasound training course
Abstract
Purpose: The objective screening of infant hips using ultrasonography (Graf method) is gaining favor in the diagnosis of developmental dysplasia of the hip in Japan. However, the accuracy of the Graf method is dependent on the examiner's experience and technique. The purpose of this study was to investigate the reproducibility of acquiring ultrasonic hip images and their evaluation after examiners attended an infant hip ultrasound training course.
Materials and methods: Ultrasonic images of 70 hips of 35 newborns who were screened by ultrasonography using the Graf method, were evaluated. The images were acquired by two inexperienced examiners who attended the training course. The inter- and intra-examiner measurement errors as well as reproducibility were calculated based on the images obtained.
Results: The intra-examiner measurement error in the acquired images of the same hip was minor. The inter-examiner measurement error was also small. The intra- and inter-examiner agreements of the Graf classification were high. The intra-examiner reproducibility of the acquired ultrasonic images was substantial, and the inter-examiner reproducibility was almost perfect.
Conclusions: Our results demonstrated that inexperienced examiners could obtain ultrasonic infant hip joint images with minor differences and high reproducibility after the training course. Our findings raise the possibility of extending the infant hip ultrasound course in Japan.
Keywords: Developmental dysplasia of the hip; Graf method; Infant hip ultrasound course; Reproducibility; Ultrasound.
Similar articles
-
Diagnosing developmental dysplasia of the hip using the Graf ultrasound method: risk and protective factor analysis in 11,820 universally screened newborns.Eur J Pediatr. 2017 Sep;176(9):1193-1200. doi: 10.1007/s00431-017-2959-z. Epub 2017 Jul 17. Eur J Pediatr. 2017. PMID: 28717864
-
[Ultrasonographic assessment of infantile hip by the Graf method].Rev Assoc Med Bras (1992). 2006 Jan-Feb;52(1):53-5. doi: 10.1590/s0104-42302006000100023. Epub 2006 Apr 10. Rev Assoc Med Bras (1992). 2006. PMID: 16622540 Portuguese.
-
Diagnostic accuracy of static graf technique of ultrasound evaluation of infant hips for developmental dysplasia.Arch Orthop Trauma Surg. 2011 Jan;131(1):53-8. doi: 10.1007/s00402-010-1100-9. Epub 2010 Apr 9. Arch Orthop Trauma Surg. 2011. PMID: 20379825
-
Ultrasonographic screening for developmental dysplasia of the hip: the Graf method revisited.Eur J Orthop Surg Traumatol. 2024 Feb;34(2):723-734. doi: 10.1007/s00590-023-03767-9. Epub 2023 Oct 26. Eur J Orthop Surg Traumatol. 2024. PMID: 37884843 Review.
-
[The use of ultrasonography in developmental dysplasia of the hip].Acta Orthop Traumatol Turc. 2007;41 Suppl 1:6-13. Acta Orthop Traumatol Turc. 2007. PMID: 17483617 Review. Turkish.
Cited by
-
Hip morphology on initial ultrasound predicts hip morphology at one year in developmental dysplasia of the hip.J Child Orthop. 2022 Nov 23;17(2):79-85. doi: 10.1177/18632521221141085. eCollection 2023 Apr. J Child Orthop. 2022. PMID: 37034190 Free PMC article.
-
The Impact of Focused Hip Ultrasound Training on Imaging Quality in Infants With Hip Dysplasia.Cureus. 2024 Nov 29;16(11):e74787. doi: 10.7759/cureus.74787. eCollection 2024 Nov. Cureus. 2024. PMID: 39737307 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources