Defining permissible limits for the combined uncertainty budget in the implementation of metrological traceability
- PMID: 29526674
- DOI: 10.1016/j.clinbiochem.2018.03.007
Defining permissible limits for the combined uncertainty budget in the implementation of metrological traceability
Abstract
In addition to the correct implementation of calibration traceability, the definition and the achievement of an appropriate analytical performance specification for the total uncertainty budget (GU) is essential to ensure that laboratory measurements are clinically usable. To understand if it is possible to fulfil these specifications, limits for combined uncertainty across the entire metrological traceability chain should be defined. We recommended that no more than one third of GU should be consumed by the uncertainty of higher order references and ≤50% of GU by the combined measurement uncertainty at the manufacturer's calibration level. The remaining allowable uncertainty should be available for random sources, i.e. for the imprecision of the commercial measuring system (including the reagent batch-to-batch variation) and the individual laboratory performance, as a safety margin to fulfil GU. Based on this approach, it is of interest to assess for each analyte measured in the clinical laboratory the status of the uncertainty budget of its measurement associated with the selected metrological traceability chain. Accordingly, we report three didactic cases that could occur in the clinical practice. This approach is very helpful to identify those analytes for which further technological improvements are probably needed to reduce uncertainty associated with their measurement.
Keywords: Measurement uncertainty; Performance specifications; Standardization.
Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Performance criteria for combined uncertainty budget in the implementation of metrological traceability.Clin Chem Lab Med. 2015 May;53(6):905-12. doi: 10.1515/cclm-2014-1240. Clin Chem Lab Med. 2015. PMID: 25870964
-
Analytical performance specifications for combined uncertainty budget in the implementation of metrological traceability.Clin Chem Lab Med. 2024 Feb 5;62(8):1497-1504. doi: 10.1515/cclm-2023-1325. Print 2024 Jul 26. Clin Chem Lab Med. 2024. PMID: 38311825
-
Measurement uncertainty: Friend or foe?Clin Biochem. 2018 Jul;57:3-6. doi: 10.1016/j.clinbiochem.2018.01.025. Epub 2018 Feb 2. Clin Biochem. 2018. PMID: 29410277 Review.
-
The role of analytical performance specifications in international guidelines and standards dealing with metrological traceability in laboratory medicine.Clin Chem Lab Med. 2024 Apr 8;62(8):1462-1469. doi: 10.1515/cclm-2023-1201. Print 2024 Jul 26. Clin Chem Lab Med. 2024. PMID: 38579121 Review.
-
Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies.Clin Chim Acta. 2014 May 15;432:55-61. doi: 10.1016/j.cca.2013.11.022. Epub 2013 Dec 1. Clin Chim Acta. 2014. PMID: 24291059
Cited by
-
Candidate High-Resolution Mass Spectrometry-Based Reference Method for the Quantification of Procalcitonin in Human Serum Using a Characterized Recombinant Protein as a Primary Calibrator.Anal Chem. 2022 Mar 15;94(10):4146-4154. doi: 10.1021/acs.analchem.1c03061. Epub 2022 Mar 2. Anal Chem. 2022. PMID: 35235744 Free PMC article.
-
Estimation of the measurement uncertainty and practical suggestion for the description of the metrological traceability in clinical laboratories.Biochem Med (Zagreb). 2021 Feb 15;31(1):010501. doi: 10.11613/BM.2021.010501. Epub 2020 Dec 15. Biochem Med (Zagreb). 2021. PMID: 33380886 Free PMC article. Review.
-
IFCC Working Group Recommendations for Correction of Bias Caused by Noncommutability of a Certified Reference Material Used in the Calibration Hierarchy of an End-User Measurement Procedure.Clin Chem. 2020 Jun 1;66(6):769-778. doi: 10.1093/clinchem/hvaa048. Clin Chem. 2020. PMID: 32335671 Free PMC article.
-
Advancing Accuracy in Chronic Kidney Disease Diagnosis and Management: Reference Materials and Reference Measurement Procedures for Clinical Markers.Ann Lab Med. 2025 Jul 1;45(4):367-380. doi: 10.3343/alm.2024.0583. Epub 2025 Jun 18. Ann Lab Med. 2025. PMID: 40528407 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical