Laser Doppler velocimetry: the problem of fibre movement artefact
- PMID: 2952839
- DOI: 10.1016/0141-5425(87)90030-6
Laser Doppler velocimetry: the problem of fibre movement artefact
Abstract
The problem of fibre movement artefact in laser Doppler velocimetry recordings of skin blood flow has been investigated. Beat frequency spectra were obtained for a stationary target, unheated skin, heated skin (43.5 degrees C), with and without blood flow occluded for various induced amounts of fibre movement. Possible methods for either eliminating, or obtaining an indicator of, fibre movement artefact were considered. The solution proposed is to incorporate additional fibres terminating within the transducer to permit an index of fibre movement to be obtained that is independent of blood flow.
Similar articles
-
Dual diode transducer for laser Doppler skin blood velocimeter.J Biomed Eng. 1984 Jan;6(1):75-7. doi: 10.1016/0141-5425(84)90014-1. J Biomed Eng. 1984. PMID: 6694372
-
Laser Doppler measurements of blood flow in skin tissue.J Biomed Eng. 1985 Jul;7(3):225-32. doi: 10.1016/0141-5425(85)90023-8. J Biomed Eng. 1985. PMID: 4033098
-
Laser Doppler velocimetry in critically ill patients.Crit Care Med. 1987 Aug;15(8):780-3. doi: 10.1097/00003246-198708000-00015. Crit Care Med. 1987. PMID: 2956064
-
Use of Doppler velocimetry in diagnosis and prognosis of intrauterine growth restriction (IUGR): A Review.J Neonatal Perinatal Med. 2016 May 18;9(2):117-26. doi: 10.3233/NPM-16915132. J Neonatal Perinatal Med. 2016. PMID: 27197939 Review.
-
Doppler measurements of maternal and fetal blood flow.Clin Obstet Gynecol. 1987 Dec;30(4):948-55. doi: 10.1097/00003081-198712000-00018. Clin Obstet Gynecol. 1987. PMID: 3319325 Review.
Cited by
-
Increased skin blood flow during low intensity vibration in human participants: Analysis of control mechanisms using short-time Fourier transform.PLoS One. 2018 Jul 12;13(7):e0200247. doi: 10.1371/journal.pone.0200247. eCollection 2018. PLoS One. 2018. PMID: 30001409 Free PMC article.
-
Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging.Med Biol Eng Comput. 2004 Nov;42(6):770-6. doi: 10.1007/BF02345210. Med Biol Eng Comput. 2004. PMID: 15587468
-
Fibre-optics and optical sensors in medicine.Med Biol Eng Comput. 1987 Nov;25(6):597-604. doi: 10.1007/BF02447325. Med Biol Eng Comput. 1987. PMID: 3333170 Review. No abstract available.
-
Wearable Laser Doppler Flowmetry Sensor: A Feasibility Study with Smoker and Non-Smoker Volunteers.Biosensors (Basel). 2020 Dec 7;10(12):201. doi: 10.3390/bios10120201. Biosensors (Basel). 2020. PMID: 33297337 Free PMC article.
-
Detection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler Flowmeter.Sensors (Basel). 2015 Oct 5;15(10):25507-19. doi: 10.3390/s151025507. Sensors (Basel). 2015. PMID: 26445047 Free PMC article. Clinical Trial.