Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT
- PMID: 29528711
- DOI: 10.2214/AJR.17.18248
Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT
Abstract
Objective: The purpose of this study is to investigate the magnitude of differences between attenuation values measured on virtual unenhanced images and true unenhanced images obtained using third-generation dual-source dual-energy CT (DECT).
Subjects and methods: A total of 83 patients requiring thoracoabdominal CT for cancer workup were included in this prospective study. CT examinations included true unenhanced acquisitions (tube potential, 120 kVp) and arterial and portal phase dual-energy CT (DECT) acquisitions (tube potential, 100 kVp and Sn 150 kVp [where Sn denotes the interposition of a tin filter in the high-energy beam]; tube current-exposure time product, 190 and 95 mAs). Virtual unenhanced images were created using two commercially available DECT postprocessing algorithms, one of which was designed to create liver images (hereafter referred to as VNC1 images) and the other of which was designed to create images of organs containing minor amounts of fat (hereafter referred to as VNC2 images). Attenuation values on the liver, spleen, paraspinal muscles, retroperitoneal fat, renal cortex and medulla, and gallbladder and bladder lumens were measured.
Results: The attenuation values of all tissues were significantly different between virtual unenhanced and true unenhanced images (p = < 0.001-0.042), except for the liver and spleen in the portal phase and muscles in both phases. When statistically significant, correlations between these differences and body mass index (weight in kilograms divided by the square of height in meters) depended on the tissue imaged and algorithm used. The percentage of cases in which these differences were 10 HU or greater was 1% for the liver and approximately 5% for the spleen and muscles, regardless of the algorithm and phase, but on VNC1 images it reached approximately 30% for the kidney, 70% for the gallbladder and bladder, and depending on the phase, 40-70% for fat. On VNC2 images, the percentage of cases in which these differences were 20 HU or greater was approximately 90% for fat.
Conclusion: Abdominal virtual unenhanced images obtained with third-generation dual-source DECT still should not replace true unenhanced images because of substantial differences in attenuation measurements for fluid, fat, and renal tissues.
Keywords: abdomen; dual-energy CT; true enhanced imaging; virtual unenhanced imaging.
Similar articles
-
Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT.Abdom Radiol (NY). 2017 Mar;42(3):710-717. doi: 10.1007/s00261-016-0991-5. Abdom Radiol (NY). 2017. PMID: 27864600
-
Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT.Abdom Radiol (NY). 2017 Mar;42(3):702-709. doi: 10.1007/s00261-016-1036-9. Abdom Radiol (NY). 2017. PMID: 28084546
-
Virtual unenhanced phase with spectral dual-energy CT: Is it an alternative to conventional true unenhanced phase for abdominal tissues?Diagn Interv Imaging. 2019 Sep;100(9):503-511. doi: 10.1016/j.diii.2019.04.007. Epub 2019 May 31. Diagn Interv Imaging. 2019. PMID: 31155514
-
Dual-energy CT applications in the abdomen.AJR Am J Roentgenol. 2012 Nov;199(5 Suppl):S64-70. doi: 10.2214/AJR.12.9196. AJR Am J Roentgenol. 2012. PMID: 23097169 Review.
-
Applications of dual-energy CT in emergency radiology.AJR Am J Roentgenol. 2014 Apr;202(4):W314-24. doi: 10.2214/AJR.13.11682. AJR Am J Roentgenol. 2014. PMID: 24660729 Review.
Cited by
-
Advanced CT techniques for assessing hepatocellular carcinoma.Radiol Med. 2021 Jul;126(7):925-935. doi: 10.1007/s11547-021-01366-4. Epub 2021 May 5. Radiol Med. 2021. PMID: 33954894 Review.
-
3D printed CT-based abdominal structure mannequin for enabling research.3D Print Med. 2020 Feb 5;6(1):3. doi: 10.1186/s41205-020-0056-9. 3D Print Med. 2020. PMID: 32026130 Free PMC article.
-
Compatibility of true and virtual unenhanced attenuation in rapid kV-switching dual energy CT.Diagn Interv Radiol. 2020 Mar;26(2):95-100. doi: 10.5152/dir.2019.19345. Diagn Interv Radiol. 2020. PMID: 32116219 Free PMC article.
-
Spectral CT of the abdomen: Where are we now?Insights Imaging. 2021 Sep 27;12(1):138. doi: 10.1186/s13244-021-01082-7. Insights Imaging. 2021. PMID: 34580788 Free PMC article. Review.
-
[Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT].J Korean Soc Radiol. 2023 Jan;84(1):170-184. doi: 10.3348/jksr.2021.0193. Epub 2023 Jan 18. J Korean Soc Radiol. 2023. PMID: 36818703 Free PMC article. Korean.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical