. 2018 Jun;33(6):1904-1907.
doi: 10.1016/j.arth.2018.01.072. Epub 2018 Feb 5.

Puncture Protocol in the Diagnostic Work-Up of a Suspected Chronic Prosthetic Joint Infection of the Hip

Affiliations

Puncture Protocol in the Diagnostic Work-Up of a Suspected Chronic Prosthetic Joint Infection of the Hip

Karsten D Ottink et al. J Arthroplasty. 2018 Jun.

Abstract

Background: Diagnosing a chronic prosthetic joint infection (PJI) can be challenging. We hypothesized that obtaining preoperative tissue samples for culture in hip arthroplasty will increase the likelihood of diagnosing an infection before revision surgery. The aim of this cohort study was to determine the diagnostic accuracy of 2 tissue acquiring biopsy strategies to diagnose a PJI.

Methods: Patients with a painful hip arthroplasty, in which a chronic PJI was suspected, were included. Tissue samples were obtained either by ultrasound guidance with a 16-Gauge needle (2012-2013) or in the operating room with a thick-bore needle (2013-2016). Revision surgery tissue biopsies were used as the gold standard. Sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were calculated.

Results: A total of 16 patients in the ultrasound cohort and 29 patients in the surgical cohort were included. Thirty-one percent (n = 14) were finally diagnosed with a PJI. The addition of thick bore needle tissue biopsies resulted in 9% more diagnosed PJIs compared with synovial fluid alone. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio was 33%, 85%, 33%, 85%, 2.2, and 0.8, respectively, for the ultrasound-guided biopsy cohort and 82%, 100%, 100%, 90%, infinite, and 0.2, respectively, for the surgical biopsy cohort.

Conclusion: Obtaining multiple good quality tissue biopsies in a sterile environment will contribute to the diagnosis of a chronic PJI of the hip, with a higher diagnostic accuracy compared with ultrasound-guided thin needle biopsies and compared with synovial fluid culture alone.

Keywords: PJI; biopsy; culture; diagnosis; prosthetic joint infection; total hip arthroplasty.

PubMed Disclaimer

MeSH terms

LinkOut - more resources