Reliability of single office blood pressure measurements
- PMID: 29530989
- DOI: 10.1136/heartjnl-2017-312523
Reliability of single office blood pressure measurements
Abstract
Objectives: Standard operating procedures for office blood pressure measurement (OBPM) vary greatly between guidelines and studies. We aimed to compare the difference between a single OBPM and the mean of the three following measurements. Further, we studied how many patients with possible hypertension may be missed due to short-term masked hypertension (STMH) and how many might be overdiagnosed due to short-term white coat hypertension (STWCH).
Design and setting: In this cross-sectional, single-centre trial, 1000 adult subjects were enrolled. After 5 min of rest, four sequential standard OBPMs were performed at 2 min intervals in a quiet room in sitting position. We compared the first (fBPM) to the mean of the second to fourth measurement (mBPM). STMH was defined as fBPM <140 mm Hg systolic and <90 mm Hg diastolic and mBPM systolic ≥140 mm Hg or diastolic ≥90 mm Hg. STWCH was defined as fBPM systolic ≥140 mm Hg or diastolic ≥90 mm Hg and mBPM <140 mm Hg systolic and <90 mm Hg diastolic.
Results: Complete measurements were available in 802 subjects. Between fBPM and mBPM, 662 (82.5%), 441 (55%) and 208 (25.9%) subjects showed a difference in systolic and 531 (66.2%), 247 (30.8%) and 51 (6.4%) in diastolic blood pressure (BP) values of >2 mm Hg, >5 mm Hg and >10 mm Hg, respectively. In 3.4% of initially normotensives STMH and in 34.3% of initially hypertensives, STWCH was apparent.
Conclusions: There are significant differences between a single OBPM and the mean of consecutive BP measurements. Our study provides evidence that a single OBPM should not be the preferred method and should be discouraged in future guidelines.
Trial registration number: NCT02552030;Results.
Keywords: cardiac risk factors and prevention; hypertension.
© Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Conflict of interest statement
Competing interests: None declared.
Comment in
-
Blood pressure measurements for treating hypertension: which method counts the most?Heart. 2018 Jul;104(14):1142-1143. doi: 10.1136/heartjnl-2018-312963. Epub 2018 Mar 19. Heart. 2018. PMID: 29555824 No abstract available.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical