. 2018 Mar 12;42(4):76.
doi: 10.1007/s10916-018-0928-3.

Development of A Textile Capacitive Proximity Sensor and Gait Monitoring System for Smart Healthcare

Affiliations

Development of A Textile Capacitive Proximity Sensor and Gait Monitoring System for Smart Healthcare

Se Dong Min et al. J Med Syst. .

Abstract

Gait is not only one of the most important functions and activities in daily life but is also a parameter to monitor one's health status. We propose a single channel capacitive proximity pressure sensor (TCPS) and gait monitoring system for smart healthcare. Insole-type TCPS (270 mm in length) was designed consisting of three layers including two shield layers and a sensor layer. Analyzing the step count and stride time are the basic indicators in gait analysis, thus they were selected as evaluation indicators. A total of 12 subjects participated in the experiment to evaluate the resolution of our TCPS. To evaluate the accuracy of TCPS, step count and its error rates were simultaneously detected by naked eye, ZIKTO Walk (ZIKTO Co., Korea), and HJ-203-K pedometer (Omron Co., Japan) as reference. Results showed that the error rate of 1.77% in TCPS was lower than those of other devices and correlation coefficient was 0.958 (p-value = 0.000). ZIKTO Walk and pedometer do not provide information on stride time, therefore it was detected by F-scan (Tekscan, USA) to evaluate the performance of TCPS. As a result, error rate of stride time measured by TCPS was found to be 1% and the correlation coefficient was 0.685 (p-value = 0.000). According to these results, our proposed system may be helpful in development of gait monitoring and measurement system as smart healthcare.

Keywords: Capacitive Proximity Sensor; Conductive Textile; Gait; Situation; Smart Healthcare.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Eur J Neurosci. 2008 Apr;27(8):1999-2006 - PubMed
    1. IEEE Trans Inf Technol Biomed. 2009 Sep;13(5):810-7 - PubMed
    1. J Med Biol Eng. 2016;36:168-177 - PubMed
    1. Stud Health Technol Inform. 2004;108:253-9 - PubMed
    1. Sensors (Basel). 2014 Feb 19;14(2):3362-94 - PubMed

LinkOut - more resources