Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
- PMID: 29534739
- PMCID: PMC5851252
- DOI: 10.1186/s12985-018-0951-5
Comparison of two different combined test strips with fluorescent microspheres or colored microspheres as tracers for rotavirus and adenovirus detection
Abstract
Background: Rotavirus (RV) and enteric adenovirus (AdV) mainly cause infantile infectious gastroenteritis. Several separate test methods for the detection of RV or AdV are currently available, but few tests are able to simultaneously detect both RV and AdV viruses, especially in primary medical institutions.
Methods: The present study was mainly designed to compare the performance of two combined test strips for the detection of RV and AdV: a rotavirus-adenovirus strip with fluorescent microspheres for tracers (FMT); and the CerTest rotavirus-adenovirus blister strip with colored microspheres for tracers (CMT). To test the strips cultures of RV, AdV and from other enteric pathogens were used, in addition to 350 stool specimens from 45 symptomatic patients with gastrointestinal infections.
Results: Detection thresholds for RV and AdV cultures using serial dilutions showed that the sensitivity of FMT was significantly higher than that of CMT (both P < 0.05). Specificity evaluation demonstrated that with culture mixtures of Coxsackie (A16), ECHO (type30), and entero- (EV71) viruses there was no detection of cross reaction using the two test strips, i.e., all the results were negative. With regard to the detection of RV in 350 clinical specimens, the total coincidence rate was 92.9%, the positive coincidence rate was 98.2%, and the negative coincidence rate was 90.8%. With regard to AdV detection, the total coincidence rate was 95.4%, the positive coincidence rate was 95.2%, and the negative coincidence rate was 95.5%.
Conclusions: FMT performed better than CMT with regard to the combined detection of RV and AdV.
Keywords: Adenovirus; Colored microspheres; Fluorescent microspheres; Rotavirus; Sensitivity; Specificity.
Conflict of interest statement
Ethics approval and consent to participate
Procedures were reviewed and approved by the Committee of the Affiliated Hospital of Guangdong Medical University.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Figures

Similar articles
-
Comparison of the detection performance of two different one-step-combined test strips with fluorescent microspheres or colored microspheres as tracers for influenza A and B viruses.Virol J. 2019 Jul 19;16(1):91. doi: 10.1186/s12985-019-1190-0. Virol J. 2019. PMID: 31324259 Free PMC article.
-
Evaluation of the AMP rapid test ROTA/ADENOVIRUS for simultaneous detection of rotavirus and adenovirus in stool samples.Eur J Clin Microbiol Infect Dis. 2025 Apr;44(4):839-845. doi: 10.1007/s10096-025-05042-7. Epub 2025 Jan 24. Eur J Clin Microbiol Infect Dis. 2025. PMID: 39853641
-
Effect of COVID-19 protective measures on the epidemiology characteristics of rotavirus, adenovirus, and coinfections among pediatric patients with acute gastroenteritis in Hangzhou, China.Microbiol Spectr. 2024 Mar 5;12(3):e0400723. doi: 10.1128/spectrum.04007-23. Epub 2024 Feb 12. Microbiol Spectr. 2024. PMID: 38345390 Free PMC article.
-
Evaluation of Immunochromatographic Tests for Detection of a Wide Variety of Group A Rotavirus Genotypes and Adenovirus.Clin Lab. 2019 Dec 1;65(12). doi: 10.7754/Clin.Lab.2019.190415. Clin Lab. 2019. PMID: 31850714
-
[Adenoviruses from stool samples in hospital units. Comparison with main pathogens in gastroenteritis (rotavirus, Campylobacter, Salmonella)].Pathol Biol (Paris). 1995 Sep;43(7):601-10. Pathol Biol (Paris). 1995. PMID: 8570265 Review. French.
Cited by
-
Rapid detection of avian leukosis virus using a fluorescent microsphere immunochromatographic test strip assay.Poult Sci. 2019 Dec 1;98(12):6492-6496. doi: 10.3382/ps/pez547. Poult Sci. 2019. PMID: 31553793 Free PMC article.
-
Development and Evaluation of a Nanoparticle-Based Immunoassay for Rotavirus Detection: A Suitable Alternative to ELISA and PCR in Low-Income Setting.Methods Protoc. 2025 Jul 17;8(4):81. doi: 10.3390/mps8040081. Methods Protoc. 2025. PMID: 40700319 Free PMC article.
-
Evaluation of the Ridaquick Rotavirus/Adenovirus Immuno-Chromatographic Assay in Real-Life Situation.Pathogens. 2021 Sep 18;10(9):1213. doi: 10.3390/pathogens10091213. Pathogens. 2021. PMID: 34578247 Free PMC article.
-
Comparison of the detection performance of two different one-step-combined test strips with fluorescent microspheres or colored microspheres as tracers for influenza A and B viruses.Virol J. 2019 Jul 19;16(1):91. doi: 10.1186/s12985-019-1190-0. Virol J. 2019. PMID: 31324259 Free PMC article.
References
-
- Fletcher S, Sibbritt D, Stark D, Harkness J, Rawlinson W, Andresen D, et al. Descriptive epidemiology of infectious gastrointestinal illnesses in Sydney, Australia, 2007-2010. Western Pacific surveillance and response journal : WPSAR. 2015;6:7–16. doi: 10.5365/wpsar.2015.6.2.006. - DOI - PMC - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical