Change of apheresis device decreased the incidence of severe acute graft-versus-host disease among patients after allogeneic stem cell transplantation with sibling donors
- PMID: 29536557
- DOI: 10.1111/trf.14579
Change of apheresis device decreased the incidence of severe acute graft-versus-host disease among patients after allogeneic stem cell transplantation with sibling donors
Abstract
Background: The composition of the graft used for allogeneic hematopoietic stem cell transplantation (HSCT) is important for the treatment outcome. Different apheresis devices may yield significant differences in peripheral blood stem cell graft cellular composition. We compared stem cell grafts produced by Cobe Spectra (Cobe) and Spectra Optia (Optia) with use of the mononuclear cell (MNC) protocol, and evaluated clinical outcome parameters such as graft-versus-host disease (GvHD), transplant-related mortality (TRM), relapse, and overall survival.
Study design and methods: During 5 years, 31 Cobe Spectra and 40 Spectra Optia grafts were analyzed for CD34, CD3, CD4, CD8, CD19, and CD56 cell content. Clinical outcome parameters were correlated and compared between the two patient groups using different apheresis devices.
Results: Optia grafts contained fewer lymphocytes compared to Cobe (p < 0.001). Optia grafts had a significantly lower incidence of acute GvHD Grades II through IV (Cobe 45% vs. Optia 23%; p = 0.039) and TRM (16% vs. 2.5%; p < 0.05) but higher chronic GvHD (32% vs. 67%; p = 0.005) compared to Cobe grafts. Finally, the multivariate analysis showed a significant correlation among the different apheresis devices and both acute GvHD II through IV and severe chronic GvHD. The multivariate analysis also showed a significant correlation between the CD3+ cell dose and the incidence of severe acute GvHD.
Conclusion: Optia-obtained grafts yielded a lower acute GvHD Grades II-IV and TRM risk, but had no impact on relapse or overall survival in this study. Understanding and further improvement of peripheral blood stem cell (PBSC) apheresis techniques may be used in the future to personalize HSCT by, for example, fine-tuning the GvHD incidence.
© 2018 AABB.
Similar articles
-
Superior GVHD-free, relapse-free survival for G-BM to G-PBSC grafts is associated with higher MDSCs content in allografting for patients with acute leukemia.J Hematol Oncol. 2017 Jul 4;10(1):135. doi: 10.1186/s13045-017-0503-2. J Hematol Oncol. 2017. PMID: 28676100 Free PMC article. Clinical Trial.
-
High CD3+ and CD34+ peripheral blood stem cell grafts content is associated with increased risk of graft-versus-host disease without beneficial effect on disease control after reduced-intensity conditioning allogeneic transplantation from matched unrelated donors for acute myeloid leukemia - an analysis from the Acute Leukemia Working Party of the European Society for Blood and Marrow Transplantation.Oncotarget. 2016 May 10;7(19):27255-66. doi: 10.18632/oncotarget.8463. Oncotarget. 2016. PMID: 27036034 Free PMC article.
-
The importance of graft cell composition in outcome after allogeneic stem cell transplantation in patients with malignant disease.Clin Transplant. 2019 Jun;33(6):e13537. doi: 10.1111/ctr.13537. Epub 2019 May 7. Clin Transplant. 2019. PMID: 30873642
-
Graft Source Choice.Adv Exp Med Biol. 2025;1475:57-75. doi: 10.1007/978-3-031-84988-6_4. Adv Exp Med Biol. 2025. PMID: 40488824 Review.
-
A systematic literature review of incidence, mortality, and relapse of patients diagnosed with chronic graft versus host disease.Expert Rev Hematol. 2019 May;12(5):311-323. doi: 10.1080/17474086.2019.1605288. Epub 2019 Apr 19. Expert Rev Hematol. 2019. PMID: 30955381
Cited by
-
Individualization of Hematopoietic Stem Cell Transplantation Using Alpha/Beta T-Cell Depletion.Front Immunol. 2019 Feb 11;10:189. doi: 10.3389/fimmu.2019.00189. eCollection 2019. Front Immunol. 2019. PMID: 30804948 Free PMC article.
-
The efficiency of human umbilical cord mesenchymal stem cells as a salvage treatment for steroid-refractory acute graft-versus-host disease.Clin Exp Med. 2023 Oct;23(6):2561-2570. doi: 10.1007/s10238-022-00983-1. Epub 2023 Jan 4. Clin Exp Med. 2023. PMID: 36598673
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials