The value of 99mTc-MDP bone SPECT/CT in evaluation of patients with painful knee prosthesis
- PMID: 29553970
- DOI: 10.1097/MNM.0000000000000825
The value of 99mTc-MDP bone SPECT/CT in evaluation of patients with painful knee prosthesis
Abstract
Objective: The purpose of this study was to assess the incremental value of technetium-99m-methyl diphosphonate (Tc-MDP) single-photon emission computed tomography/computed tomography (SPECT/CT) over Tc-MDP two-phase bone scan (TPBS) in the assessment of the patients with pain following knee arthroplasty.
Patients and methods: Tc-MDP TPBS and Tc-MDP SPECT/CT were performed in 49 patients with knee pain after knee arthroplasty. The scans were reviewed by two readers (nuclear medicine physician and musculoskeletal radiologist). Tc-MDP SPECT/CT studies were interpreted in conjunction with TPBS in this retrospective study to identify the pain generator in painful knee prosthesis. The final diagnosis was established based on a combination of histopathological/cytological findings, other imaging findings (e.g. MRI, radiolabelled white scan), clinical decisions, and management outcomes (including subsequent intraoperative findings).
Results: In diagnosing infection or aseptic loosening, a definitive outcome regarding the presence/absence of aseptic loosening or periprosthetic infection was obtained in 41 patients. (a) Sensitivity of Tc-MDP SPECT/CT [100%; 95% confidence interval (CI): 66.4-100%] was higher than Tc-MDP TPBS (88.9%; 95% CI: 51.8-99.7%). (b) Specificity of Tc-MDP SPECT/CT (75%; 95% CI: 53.3-90.2%) was considerably higher than Tc-MDP TPBS (30%; 95% CI: 11.9-54.3%). Alternative diagnoses were identified in 21/49 (43%) patients on Tc-MDP SPECT/CT, which could not be ascertained on Tc-MDP TPBS alone.
Conclusion: Tc-MDP SPECT/CT has better sensitivity and specificity compared with Tc-MDP TPBS in diagnosis of aseptic loosening and periprosthestic infection in patients with painful knee arthroplasty. Tc-MDP SPECT/CT identified alternative causes of pain in 43% of patients, which was not identified by Tc-MDP TPBS.
Similar articles
-
The role of bone SPECT/CT in the evaluation of painful joint prostheses.Nucl Med Commun. 2015 Sep;36(9):931-40. doi: 10.1097/MNM.0000000000000348. Nucl Med Commun. 2015. PMID: 26049374
-
Accurate characterization of 99mTc-MDP uptake in extraosseous neoplasm mimicking bone metastasis on whole-body bone scan: contribution of SPECT/CT.BMC Med Imaging. 2019 May 30;19(1):44. doi: 10.1186/s12880-019-0345-1. BMC Med Imaging. 2019. PMID: 31146746 Free PMC article.
-
Painful knee arthroplasty.J Nucl Med Technol. 2014 Jun;42(2):122-3. doi: 10.2967/jnmt.113.132753. Epub 2014 Mar 13. J Nucl Med Technol. 2014. PMID: 24627412
-
Bone scan in painful knee arthroplasty: obsolete or actual examination?Acta Biomed. 2017 Jun 7;88(2S):68-77. doi: 10.23750/abm.v88i2-S.6516. Acta Biomed. 2017. PMID: 28657567 Free PMC article. Review.
-
Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis.J Nucl Med Technol. 2025 Mar 5;53(1):44-49. doi: 10.2967/jnmt.123.266050. J Nucl Med Technol. 2025. PMID: 39909585
Cited by
-
Computed Tomography (CT) Protocols Associated with Cardiac and Bone Single-Photon Emission Computed Tomography/CT (SPECT/CT) in Korea.Nucl Med Mol Imaging. 2020 Jun;54(3):139-146. doi: 10.1007/s13139-020-00644-9. Epub 2020 Jun 1. Nucl Med Mol Imaging. 2020. PMID: 32582397 Free PMC article.
-
Technetium-99m-methylene diphosphonate single photon emission computed tomography/computed tomography combined with prostate-specific antigen/free prostate-specific antigen ratio for bone metastasis of prostate cancer.World J Clin Cases. 2024 Jul 16;12(20):4082-4090. doi: 10.12998/wjcc.v12.i20.4082. World J Clin Cases. 2024. PMID: 39015893 Free PMC article.
-
Bone SPECT/CT has excellent sensitivity and specificity for diagnosis of loosening and patellofemoral problems after total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2020 Apr;28(4):1029-1035. doi: 10.1007/s00167-019-05609-w. Epub 2019 Jul 1. Knee Surg Sports Traumatol Arthrosc. 2020. PMID: 31263926
-
The role of SPECT/CT in painful, noninfected knees after knee arthroplasty: a systematic review and meta-analysis-a diagnostic test accuracy review.J Orthop Surg Res. 2023 Mar 21;18(1):223. doi: 10.1186/s13018-023-03687-8. J Orthop Surg Res. 2023. PMID: 36945001 Free PMC article.
-
Can bone scintigraphy reflect the progression of osteoarthritis after unicompartmental knee arthroplasty?PLoS One. 2023 Nov 8;18(11):e0288616. doi: 10.1371/journal.pone.0288616. eCollection 2023. PLoS One. 2023. PMID: 37939074 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical