Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jun:363:78-84.
doi: 10.1016/j.heares.2018.03.007. Epub 2018 Mar 12.

Head shadow enhancement with low-frequency beamforming improves sound localization and speech perception for simulated bimodal listeners

Affiliations

Head shadow enhancement with low-frequency beamforming improves sound localization and speech perception for simulated bimodal listeners

Benjamin Dieudonné et al. Hear Res. 2018 Jun.

Abstract

Many hearing-impaired listeners struggle to localize sounds due to poor availability of binaural cues. Listeners with a cochlear implant and a contralateral hearing aid - so-called bimodal listeners - are amongst the worst performers, as both interaural time and level differences are poorly transmitted. We present a new method to enhance head shadow in the low frequencies. Head shadow enhancement is achieved with a fixed beamformer with contralateral attenuation in each ear. The method results in interaural level differences which vary monotonically with angle. It also improves low-frequency signal-to-noise ratios in conditions with spatially separated speech and noise. We validated the method in two experiments with acoustic simulations of bimodal listening. In the localization experiment, performance improved from 50.5 to 26.8 root-mean-square error compared with standard omni-directional microphones. In the speech-in-noise experiment, speech was presented from the frontal direction. Speech reception thresholds improved by 15.7 dB SNR when the noise was presented from the cochlear implant side, improved by 7.6 dB SNR when the noise was presented from the hearing aid side, and was not affected when noise was presented from all directions. Apart from bimodal listeners, the method might also be promising for bilateral cochlear implant or hearing aid users. Its low computational complexity makes the method suitable for application in current clinical devices.

Keywords: Directional hearing; Enhancement of interaural level differences; Head shadow enhancement; Sound localization; Speech in noise; Speech intelligibility.

PubMed Disclaimer

Similar articles

Cited by

Publication types