Abstract
The innovative vascular unloading technology (VUT) allows continuous noninvasive arterial blood pressure (AP) monitoring. We aimed to investigate whether the VUT enables AP changes to be detected earlier compared with intermittent AP monitoring in patients undergoing gastrointestinal endoscopy. In this prospective observational study, we recorded continuous AP measurements with the VUT (CNAP system; CNSystems Medizintechnik AG, Graz, Austria) and intermittent AP measurements with upper arm cuff oscillometry in 90 patients undergoing complex gastrointestinal endoscopy (Department of Interventional Endoscopy at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany). A "hypotensive phase" was defined as a time period of at least 30 s during which ≥ 50% of the VUT-AP values were in a predefined range of hypotension, i.e., AP value a) ≥ 10% below the last oscillometric value and b) ≤ 65 mmHg for mean AP or ≤ 90 mmHg for systolic AP. In the 5-min-interval between two oscillometric measurements, one or more hypotensive phases were detected in 26 patients (29%) for mean AP and in 27 patients (30%) for systolic AP. Hypotensive phases had a mean duration of 195 ± 99 s for mean AP and 197 ± 97 s for systolic AP with a mean procedure duration of 36 (± 21) min. Continuous noninvasive AP monitoring using the VUT enables hypotensive phases to be detected earlier compared with intermittent AP monitoring during complex gastrointestinal endoscopy. These hypotensive phases may be missed or only belatedly recognized with intermittent AP monitoring. Continuous noninvasive AP measurement facilitates detecting hemodynamic instability more rapidly and therefore may improve patient safety.
Keywords: Arterial pressure; Hemodynamic monitoring; Hypotension; Oscillometry; Volume clamp method.
Similar articles
-
Noninvasive continuous versus intermittent arterial pressure monitoring: evaluation of the vascular unloading technique (CNAP device) in the emergency department.Scand J Trauma Resusc Emerg Med. 2014 Jan 29;22:8. doi: 10.1186/1757-7241-22-8. Scand J Trauma Resusc Emerg Med. 2014. PMID: 24472659 Free PMC article.
-
Noninvasive continuous monitoring versus intermittent oscillometric measurements for the detection of hypotension during digestive endoscopy.PLoS One. 2020 Oct 2;15(10):e0240241. doi: 10.1371/journal.pone.0240241. eCollection 2020. PLoS One. 2020. PMID: 33007051 Free PMC article.
-
Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement.Br J Anaesth. 2012 Sep;109(3):413-9. doi: 10.1093/bja/aes224. Epub 2012 Jul 12. Br J Anaesth. 2012. PMID: 22798273
-
Update on Finger-Application-Type Noninvasive Continuous Hemodynamic Monitors (CNAP and ccNexfin): Physical Principles, Validation, and Clinical Use.Semin Cardiothorac Vasc Anesth. 2017 Dec;21(4):321-329. doi: 10.1177/1089253217708620. Epub 2017 May 10. Semin Cardiothorac Vasc Anesth. 2017. PMID: 28490233 Review.
-
Noninvasive BP Monitoring in the Critically Ill: Time to Abandon the Arterial Catheter?Chest. 2018 Apr;153(4):1023-1039. doi: 10.1016/j.chest.2017.10.030. Epub 2017 Nov 3. Chest. 2018. PMID: 29108815 Review.
Cited by
-
Wearable skin-like optoelectronic systems with suppression of motion artifacts for cuff-less continuous blood pressure monitor.Natl Sci Rev. 2020 May;7(5):849-862. doi: 10.1093/nsr/nwaa022. Epub 2020 Feb 14. Natl Sci Rev. 2020. PMID: 34692108 Free PMC article.
-
Orthostatic-dependent cardiopulmonary responses among trained females during intensity matched resistance exercises in a pilot randomized crossover study.Sci Rep. 2025 Jun 23;15(1):20248. doi: 10.1038/s41598-025-04383-9. Sci Rep. 2025. PMID: 40550872 Free PMC article. Clinical Trial.
-
Patent landscape review of non-invasive medical sensors for continuous monitoring of blood pressure and their validation in critical care practice.Front Med (Lausanne). 2023 Jul 11;10:1138051. doi: 10.3389/fmed.2023.1138051. eCollection 2023. Front Med (Lausanne). 2023. PMID: 37497278 Free PMC article. Review.
-
Effect of Remimazolam versus Propofol on Hemodynamics in Elderly Hypertensive Patients Undergoing Gastroenteroscopy: A Multicenter, Randomized Controlled Clinical Trial.Drug Des Devel Ther. 2025 Jul 28;19:6423-6434. doi: 10.2147/DDDT.S532746. eCollection 2025. Drug Des Devel Ther. 2025. PMID: 40756269 Free PMC article. Clinical Trial.
-
Predictors of sepsis, intensive care unit admission, and death in patients hospitalized for complicated skin and soft tissue infections: Retrospective study at a large tertiary-care center.SAGE Open Med. 2025 Apr 26;13:20503121251336069. doi: 10.1177/20503121251336069. eCollection 2025. SAGE Open Med. 2025. PMID: 40297785 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources