Tissue oximetry by diffusive reflective visible light spectroscopy: Comparison of algorithms and their robustness
- PMID: 29575571
- DOI: 10.1002/jbio.201700367
Tissue oximetry by diffusive reflective visible light spectroscopy: Comparison of algorithms and their robustness
Abstract
It is essential to measure tissue oxygen saturation (StO2 ) locally and in thin layers of tissue, for example, the bronchial mucosa, skin flaps and small bones. Visible light spectroscopy (VLS) with a shallow penetration depth is suitable method. Although several VLS algorithms have been developed and described, they have not yet been compared to each other. This hinders attempts to compare the clinical results obtained by different algorithms. To address this issue, we compared the algorithms of Harrison, Knoefel, Pittman-Duling, Sato and our OxyVLS oximeter, which applies the algorithm from Wodick and Lübbers, in a liquid phantom with optical properties of human tissue. We generally observed considerable differences between the algorithms, which were StO2 dependent. Exceptions were OxyVLS and Sato, showing a high level of agreement with negligible StO2 dependency. In spite of the considerable deviation between the other algorithms, the difference of StO2 between them in clinically normal StO2 was <10%. We did not observe any dependency of the algorithms on hemoglobin content of the phantom or temperature.
Keywords: liquid blood phantoms; local tissue oximetry; visible light spectroscopy.
© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Similar articles
-
In Vitro Validation of a New Tissue Oximeter Using Visible Light.Adv Exp Med Biol. 2022;1395:217-221. doi: 10.1007/978-3-031-14190-4_36. Adv Exp Med Biol. 2022. PMID: 36527640
-
Continuous, noninvasive, and localized microvascular tissue oximetry using visible light spectroscopy.Anesthesiology. 2004 Jun;100(6):1469-75. doi: 10.1097/00000542-200406000-00019. Anesthesiology. 2004. PMID: 15166566
-
Design of a visible-light spectroscopy clinical tissue oximeter.J Biomed Opt. 2005 Jul-Aug;10(4):44005. doi: 10.1117/1.1979504. J Biomed Opt. 2005. PMID: 16178639
-
Diffuse reflectance spectrophotometry with visible light: comparison of four different methods in a tissue phantom.Phys Med Biol. 2006 Jan 7;51(1):121-36. doi: 10.1088/0031-9155/51/1/009. Epub 2005 Dec 15. Phys Med Biol. 2006. PMID: 16357435
-
Retinal oximetry and systemic arterial oxygen levels.Acta Ophthalmol. 2018 Nov;96 Suppl A113:1-44. doi: 10.1111/aos.13932. Acta Ophthalmol. 2018. PMID: 30460761 Review.
Cited by
-
Skin Pigmentation Influence on Pulse Oximetry Accuracy: A Systematic Review and Bibliometric Analysis.Sensors (Basel). 2022 Apr 29;22(9):3402. doi: 10.3390/s22093402. Sensors (Basel). 2022. PMID: 35591092 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources