Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1987 Nov;76(5):1081-91.
doi: 10.1161/01.cir.76.5.1081.

Validation of Doppler-derived pulmonary arterial pressure in patients with ductus arteriosus under different hemodynamic states

Affiliations

Validation of Doppler-derived pulmonary arterial pressure in patients with ductus arteriosus under different hemodynamic states

N N Musewe et al. Circulation. 1987 Nov.

Abstract

Twenty-nine patients with a patent ductus arteriosus (PDA) in isolation (n = 17) or in combination with other lesions (n = 12) underwent simultaneous hemodynamic assessment and evaluation of PDA flow velocity by the Doppler method. The accuracy with which Doppler velocity across the PDA predicted pulmonary arterial pressure and the influence of PDA size and shape on the Doppler velocity-pressure relationship were examined. Seventy percent had a cone-shaped PDA (narrowest at the pulmonary artery end), and the remainder were tubular. Narrowest PDA diameter ranged from 1.5 to 9 mm (mean 3.5 mm). Peak systolic and mean pulmonary arterial pressure ranged from 10 to 116 and 8 to 72 mm Hg, respectively. Twenty-one patients (group 1) had left-to-right shunting only. The following variables showed significant correlation in this group: peak instantaneous systolic aortic-to-main pulmonary arterial (MPA) pressure gradient and maximum Doppler velocity across the PDA (slope = 1.03, SEE = 13 mm Hg, r = .94, p less than .001), mean aortic-to-MPA pressure gradient and mean Doppler velocity (slope = 1.06, SEE = 10 mm Hg, r = .95, p less than .001), and end diastolic aortic-to-MPA pressure gradient and minimum Doppler velocity (slope = 1.12, SEE = 8 mm Hg, r = .96, p less than .001). Eight patients (group 2) had bidirectional shunting. In this group peak instantaneous aortic-to-MPA pressure gradient significantly correlated with maximum Doppler velocity measured from the left-to-right shunt (slope = .70, SEE = 2 mm Hg, r = .92, p less than .002) and mean pressure gradient correlated with mean Doppler velocity (slope = .83, SEE = 3 mm Hg, r = .78, p less than .003). Right-to-left Doppler velocities showed no correlation with pressures. In six patients with pulmonary hypertension Doppler velocity changes accurately predicted the effect of pulmonary vasodilation on pulmonary arterial pressure. Doppler velocity of PDA flow reliably predicts pulmonary arterial pressure over a wide range of pressures and PDA shapes and sizes.

PubMed Disclaimer

Substances

LinkOut - more resources