Relevance of n-butanol as a reference gas for odorants and complex odors
- PMID: 29595178
- DOI: 10.2166/wst.2018.061
Relevance of n-butanol as a reference gas for odorants and complex odors
Abstract
Odor analysis by olfactometry relies on the use of n-butanol as a reference compound for standardizing the selection of human panelists. This requires that human sensitivity towards n-butanol is correlated to sensitivity towards other odorants as well as complex odor mixtures. However, there is limited evidence in the literature of such correlations. In this work, datasets from three odor laboratories were investigated in order to clarify this. All panels routinely analyzed n-butanol and H2S samples. Two of the laboratories analyzed samples from pig production or industry, whereas one laboratory determined odor threshold values for typical pig production odorants. Non-significant correlations were observed in most cases and odor threshold values for structurally related compounds were not well correlated. The work presented strongly indicates that the sensitivity of odor panelists towards n-butanol is not well transferred to other odorants or odor samples. Furthermore, minimization of variance by using n-butanol is not transferable to other odorants or environmental samples. Thus, the harmonization of human panelists for odor analysis based on n-butanol does not appear to result in harmonization with respect to other odorants or odor samples.
Similar articles
-
Scents in the stack: olfactometric proficiency testing with an emission simulation apparatus.Environ Sci Pollut Res Int. 2018 Sep;25(25):24787-24797. doi: 10.1007/s11356-018-2515-z. Epub 2018 Jun 20. Environ Sci Pollut Res Int. 2018. PMID: 29926329 Free PMC article.
-
Ambient odour testing of concentrated animal feeding operations using field and laboratory olfactometers.Water Sci Technol. 2004;50(4):109-14. Water Sci Technol. 2004. PMID: 15484749
-
Key Odorants from Pig Production Based on Improved Measurements of Odor Threshold Values Combining Olfactometry and Proton-Transfer-Reaction Mass Spectrometry (PTR-MS).Sensors (Basel). 2018 Mar 6;18(3):788. doi: 10.3390/s18030788. Sensors (Basel). 2018. PMID: 29509664 Free PMC article.
-
Measurements techniques and models to assess odor annoyance: A review.Environ Int. 2020 Jan;134:105261. doi: 10.1016/j.envint.2019.105261. Epub 2019 Nov 6. Environ Int. 2020. PMID: 31704563 Review.
-
[Evaluation of methods for monitoring air concentrations of hydrogen sulfide].Med Pr. 2013;64(3):449-54. Med Pr. 2013. PMID: 24261256 Review. Polish.
Cited by
-
Calibrating canines-a universal detector calibrant for detection dogs.Front Allergy. 2024 Mar 12;5:1366596. doi: 10.3389/falgy.2024.1366596. eCollection 2024. Front Allergy. 2024. PMID: 38533355 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources