Oncentra brachytherapy planning system
- PMID: 29598924
- DOI: 10.1016/j.meddos.2018.02.011
Oncentra brachytherapy planning system
Abstract
In modern cancer management, treatment planning has progressed as a contemporary tool with all the advances in computing power in recent years. One of the advanced planning tools uses 3-dimensional (3D) data sets for accurate dose distributions in patient prescription. Among these planning processes, brachytherapy has been a very important part of a successful cancer management program, offering clinical benefits with specific or combined treatments with external beam therapy. In this chapter, we mainly discussed the Elekta Oncentra planning system, which is the main treatment planning tool for high-dose rate (HDR) modality in our facility and in many other facilities in the United States. HDR is a technically advanced form of brachytherapy; a high-intensity radiation source (3.6 mm in length) is delivered with step motor in submillimeter precision under computer guidance directly into the tumor areas while minimizing injury to surrounding normal healthy tissue. Oncentra planning is the key component to generate a deliverable brachytherapy procedure, which is executed on the microSelectron V3 remote afterloader treatment system. Creating a highly conformal plan can be a time-consuming task. The development of Oncentra software (version 4.5.3) offers a variety of useful tools that facilitate many of the clinical challenging tasks for planning, such as contouring and image reconstruction, as well as rapid planning calculations with dose and dose volume histogram analysis. Oncentra Brachy module creates workflow and optimizes the planning accuracy for wide varieties of clinical HDR treatments, such as skin, gynecologic (GYN), breast, prostate, and many other applications. The treatment file can also be transferred to the afterloader control station for speedy delivery. The design concept, calculation algorithms, and optimization modules presented some key characteristics to plan and treat the patients effectively and accurately. The dose distribution and accuracy of several clinical sample cases were discussed to illustrate the effectiveness and clinical efficacy. The American Association of Physicists in Medicine brachytherapy reports of TG-43 and TG-186 were also described and compared in evaluations of fundamental calculation methodologies.
Keywords: Brachytherapy; Oncentra; TG-186; TG-43.
Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Similar articles
-
A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.Med Phys. 2017 Nov;44(11):5961-5976. doi: 10.1002/mp.12459. Epub 2017 Oct 19. Med Phys. 2017. PMID: 28722180
-
A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.Med Phys. 2015 Jun;42(6):3048-61. doi: 10.1118/1.4921020. Med Phys. 2015. PMID: 26127057
-
Methodology for commissioning a brachytherapy treatment planning system in the era of 3D planning.Australas Phys Eng Sci Med. 2010 Dec;33(4):341-9. doi: 10.1007/s13246-010-0036-2. Epub 2010 Nov 4. Australas Phys Eng Sci Med. 2010. PMID: 21053116
-
American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning.Med Phys. 1998 Oct;25(10):1773-829. doi: 10.1118/1.598373. Med Phys. 1998. PMID: 9800687 Review.
-
Comprehensive methodology for commissioning modern 3D-image-based treatment planning systems for high dose rate gynaecological brachytherapy: A review.Phys Med. 2020 Sep;77:21-29. doi: 10.1016/j.ejmp.2020.07.031. Epub 2020 Aug 5. Phys Med. 2020. PMID: 32768917 Review.
Cited by
-
Quantitative study on dose distribution of Freiburg flap for keloid high-dose-rate brachytherapy based on MatriXX.J Appl Clin Med Phys. 2023 Sep;24(9):e14118. doi: 10.1002/acm2.14118. Epub 2023 Aug 18. J Appl Clin Med Phys. 2023. PMID: 37593834 Free PMC article.
-
Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer.J Contemp Brachytherapy. 2023 Oct;15(5):334-343. doi: 10.5114/jcb.2023.132697. Epub 2023 Oct 31. J Contemp Brachytherapy. 2023. PMID: 38026073 Free PMC article.
-
Single- versus Multi-computed Tomography Simulation for High-dose-rate Postoperative Gynecological Intracavitary Brachytherapy.J Med Phys. 2024 Jan-Mar;49(1):6-11. doi: 10.4103/jmp.jmp_130_23. Epub 2024 Mar 30. J Med Phys. 2024. PMID: 38828066 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous