. 2018 Apr;153(4):558-567.
doi: 10.1016/j.ajodo.2017.08.019.

Reliability and validity of mandibular posterior vertical asymmetry index in panoramic radiography compared with cone-beam computed tomography

Affiliations

Reliability and validity of mandibular posterior vertical asymmetry index in panoramic radiography compared with cone-beam computed tomography

Young-Sub Lim et al. Am J Orthod Dentofacial Orthop. 2018 Apr.

Abstract

Introduction: The purposes of this study were to compare the asymmetry index using panoramic radiography and cone-beam computed tomography for detecting mandibular posterior asymmetry and to evaluate the diagnostic value of the asymmetry index on panoramic radiography.

Methods: A total of 43 patients were included in this study. Ten mandibular posterior distances were measured using panoramic radiography and cone-beam computed tomography, and 10 asymmetry index values were calculated. The reliability of each asymmetry index was assessed. For evaluating validity of each asymmetry index using panoramic radiography, the paired t test and the Bland-Altman analysis were used. The accuracy of the asymmetry index and the area under the curve of receiver operator characteristic were calculated.

Results: The asymmetry index of total ramal height showed good reliability (ICC, >0.888). In condylar height 1, specificity and negative predictive value were low (0.08 and 0.17, respectively), 95% limits of agreement were ±17.9%, and area under the curve was 0.484. In total, ramal height accuracy was 0.86, and areas under the curve were 0.926 to 0.957.

Conclusions: For detecting asymmetry of the condyle region, the asymmetry index using panoramic radiography had little diagnostic value, and we recommend using cone-beam computed tomography images. However, the asymmetry index for total ramal height showed good reliability and relatively higher validity, and its diagnostic value was excellent.