Randomized Controlled Trial
. 2018 Oct;32(10):4228-4234.
doi: 10.1007/s00464-018-6169-1. Epub 2018 Mar 30.

The effect on surgical skills of expert surgeons using 3D/HD and 2D/4K resolution monitors in laparoscopic phantom tasks

Affiliations
Randomized Controlled Trial

The effect on surgical skills of expert surgeons using 3D/HD and 2D/4K resolution monitors in laparoscopic phantom tasks

Hitoshi Harada et al. Surg Endosc. 2018 Oct.

Abstract

Background: Recently, several new imaging technologies, such as three-dimensional (3D)/high-definition (HD) stereovision and high-resolution two-dimensional (2D)/4K monitors, have been introduced in laparoscopic surgery. However, it is still unclear whether these technologies actually improve surgical performance.

Methods: Participants were 11 expert laparoscopic surgeons. We designed three laparoscopic suturing tasks (task 1: simple suturing, task 2: knotting thread in a small box, and task 3: suturing in a narrow space) in training boxes. Performances were recorded by an optical position tracker. All participants first performed each task five times consecutively using a conventional 2D/HD monitor. Then they were randomly divided into two groups: six participants performed the tasks using 3D/HD before using 2D/4K; the other five participants performed the tasks using a 2D/4K monitor before the 3D/HD monitor. After the trials, we evaluated the performance scores (operative time, path length of forceps, and technical errors) and compared performance scores across all monitors.

Results: Surgical performances of participants were ranked in decreasing order: 3D/HD, 2D/4K, and 2D/HD using the total scores for each task. In task 1 (simple suturing), some surgical performances using 3D/HD were significantly better than those using 2D/4K (P = 0.017, P = 0.033, P = 0.492 for operative time, path length, and technical errors, respectively). On the other hand, with operation in narrow spaces such as in tasks 2 and 3, performances using 2D/4K were not inferior to 3D/HD performances. The high-resolution images from the 2D/4K monitor may enhance depth perception in narrow spaces and may complement stereoscopic vision almost as well as using 3D/HD.

Conclusions: Compared to a 2D/HD monitor, a 3D/HD monitor improved the laparoscopic surgical technique of expert surgeons more than a 2D/4K monitor. However, the advantage of 2D/4K high-resolution images may be comparable to a 3D/HD monitor especially in narrow spaces.

Keywords: 3D; 4K; Depth perception; Expert surgeons; Laparoscopy; Task performance.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Surg Endosc. 2017 Mar;31(3):1111-1118 - PubMed
    1. Surg Endosc. 2014 Dec;28(12):3489-93 - PubMed
    1. Langenbecks Arch Surg. 2017 May;402(3):493-500 - PubMed
    1. Surg Endosc. 2016 Jan;30(1):315-22 - PubMed
    1. Int J Surg. 2015 Feb;14:12-6 - PubMed

Publication types