. 2018 Jul;32(6):e22429.
doi: 10.1002/jcla.22429. Epub 2018 Mar 30.

An improved reference method for serum cations measurement by ion chromatography

Affiliations

An improved reference method for serum cations measurement by ion chromatography

Jihua Zou et al. J Clin Lab Anal. 2018 Jul.

Abstract

Background: To improve the accuracy of the routine methods in laboratory medicine, ion chromatography with a simple sample treatment procedure, which can completely remove the proteins and/or organics in human serum, has been developed for the determination of serum cations.

Methods: Chromatographic conditions for the separate and simultaneous determination of K, Na, Ca, and Mg were investigated. Furthermore, various factors influencing the mineralization of human serum, such as the selection and amount of oxidant, were also examined systematically and optimized.

Results: The optimized experimental conditions are as follows: 1.0 mL of serum specimen digested with 2 mL nitric acid (120°C) followed by 2 mL hydrogen peroxide (80°C). The specimens were then redissolved and determined by ion chromatography under the optimum eluent concentration of 32 mmol/L methanesulfonic acids. The measurement accuracy and precision are less than 1.0% for all the analytes by analyzing NIST certified reference materials, IFCC-RELA specimens and serum specimens. The results were also comparable with the reference values obtained by the inductively coupled plasma mass spectrometry (ICP-MS), which were found to be in good agreement.

Conclusions: Ion chromatography with a simple sample treatment procedure for the determination of cations in human serum with high sensitivity and specificity was developed. The proposed method could be recommended as a candidate reference method for the determination of serum cations.

Keywords: candidate reference method; ion chromatography; serum cations.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Serum chromatogram after complete digestion
Figure 2
Figure 2
Effect of eluent concentration on the separation of cations

References

    1. Silva JAF, Ricelli NL, Carvalho AZ, Lago CL. Improved separation of IA and IIA metal cations in matrices with high sodium concentration by capillary electrophoresis with contactless conductometric detection. J Braz Chem Soc. 2003;14:265‐268.
    1. Jia K, Zhang C, Huang X, et al. Reference intervals of serum sodium, potassium, and chlorine in Chinese Han population and comparison of two ISE methods. J Clin Lab Anal. 2015;29:226‐234. - PMC - PubMed
    1. Thienpont LM, Van Nuwenborg JE, Stockl D. Intrinsic and routine quality of serum total potassium measurement as investigated by split sample measurement with an ion chromatography candidate reference method. Clin Chem. 1998;44:849‐857. - PubMed
    1. Song Z, Xie B, Ma H, et al. Modified HPLC–ESI–MS method for glycated hemoglobin quantification based on the IFCC reference measurement procedure and its application for quantitative analyses in Clinical Laboratories of China. J Clin Lab Anal. 2016;30:457‐463. - PMC - PubMed
    1. Velapoldi RA, Paule RC, Schaffer R, Mandel J, Machlan LA, Gramlich JW. A Reference Method for the Determination of Sodium in Serum. NBS Special Publication 260‐60. Washington, DC: US Department of Commerce/National Bureau of Standards; 1978.

LinkOut - more resources