Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1987 Dec;28(12):1881-7.

Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats

Affiliations
  • PMID: 2960790
Free article
Comparative Study

Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats

J R Coveney et al. J Nucl Med. 1987 Dec.
Free article

Abstract

Technetium-99m (99mTc) mercaptoacetylglycylglycylyglycine (MAG3) in high (greater than or equal to 95%) radiochemical purity is prepared from lyophilized kits containing benzoylMAG3, sodium tartrate, lactose, and stannous chloride by adding sodium [99mTC]pertechnetate and heating the contents briefly. Constant-infusion renal whole-blood clearance obtained with [99mTc] MAG3 kits was compared with that obtained with high performance liquid chromatography (HPLC) pure [99mTc]MAG3 and with co-infused iodine-131 (131I) iodohippurate (OIH) in anesthetized rats. Average renal whole-blood clearance of [99mTc]MAG3 from kits was 3.9 +/- 0.4 ml/min/100 g body weight (mean +/- s.e.m. n = 5) and that for HPLC-pure [99mTc]MAG3 was 4.6 +/- 0.3 (n = 3). Renal whole-blood clearance ratios for [99mTc]MAG3 to co-infused iodine-131 (131I) OIH were greater than unity for both kit formulation (1.7 +/- 0.1) and HPLC-pure [99mTc]MAG3 (1.9 +/- 0.2). Differences in these two measures were not significant. Plasma binding (determined from blood drawn at the end of the infusion) of [99mTc]MAG3 prepared from both kits (75 +/- 2%, n = 4) and HPLC-separation (76 +/- 4%) were greater than that of [131I]OIH in corresponding plasma samples (31 +/- 1% and 32 +/- 2%) respectively). Renograms performed in anesthetized rats revealed no statistically significant differences between kit-prepared [99mTc]MAG3 and [131I]OIH in terms of time-to-peak renal activity (5.0 +/- 1.7 min, n = 6; and 2.2 +/- 0.2 min, n = 3, mean +/- s.e.m. for [99mTc]MAG3 and [131I]OIH, respectively), in terms of time to fall to half-maximal activity (15.3 +/- 2.4 min and 9.6 +/- 2.1 min, respectively), or in terms of fraction of peak radioactivity in right kidney (0.53 +/- 0.01 for both substances). To assess possible interference from hepatobiliary uptake and excretion in renal failure, radioactivity in liver regions of interest was followed by gamma camera scintigraphy for 30 min after intravenous injection of [131I]OIH and kit and HPLC-purified [99mTc]MAG3 in anesthetized rats rendered anephric by ligating renal peduncles. Liver activity was 25% of total for both preparations of [99mTc]MAG3 and was 22% of total for [131I]OIH. There were no significant differences among the substances.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources