Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jun:287:88-97.
doi: 10.1016/j.forsciint.2018.03.002. Epub 2018 Mar 28.

Evaluation of 1,5-anhydro-d-glucitol in clinical and forensic urine samples

Affiliations

Evaluation of 1,5-anhydro-d-glucitol in clinical and forensic urine samples

Konrad Sydow et al. Forensic Sci Int. 2018 Jun.

Abstract

Because of the lack of characteristic morphological findings post mortem diagnosis of diabetes mellitus and identification of diabetic coma can be complicated. 1,5-Anhydroglucitol (1,5-AG), the 1-deoxy form of glucose, competes with glucose for renal reabsorption. Therefore low serum concentrations of 1,5-AG, reflect hyperglycemic excursions over the prior 1-2 weeks in diabetic patients. Next to clinical applications determination of 1,5-AG can also be used in forensic analysis. To investigate the elimination of 1,5-AG, a liquid chromatographic-mass spectrometric method for the determination of 1,5-AG and creatinine in urine was developed and validated according to international guidelines. To evaluate ante mortem concentrations of 1,5-AG spot urine samples of 30 healthy subjects, 46 type 1 and 46 type 2 diabetic patients were analyzed. 1,5-AG urine concentrations of diabetic patients were significantly (p<0.001) lower (mean: 1.54μg/ml, n=92) compared to concentrations of healthy subjects (mean: 4.76μg/ml, n=30) which led to the idea that 1,5-AG urine concentrations post mortem might help in the interpretation of a diabetic coma post mortem. Urine of 47 deceased non-diabetics, 37 deceased diabetic and 9 cases of diabetic coma were measured. Comparison of blood and urine 1,5-AG concentrations in clinic samples (linear, R2=0.13) and forensic samples (linear, R2=0.02) showed no correlation. Urinary levels of 1,5-AG in deceased diabetic (mean 6.9μg/ml) and in non-diabetic patients (mean 6.3μg/ml) did not show a significant difference (p=0.752). However, urinary 1,5-AG concentrations in deceased due to diabetic coma (mean: 1.7μg/ml) were significantly lower than in non-diabetic (mean: 6.3μg/ml, p=0.039) and lower than in diabetic cases (mean: 4.7μg/ml, p=0.058). The determination of a reliable cut-off for the differentiation of diabetic to diabetic coma cases was not possible. Normalization of urinary 1,5-AG concentrations with the respective creatinine concentrations did not show any gain of information. In clinical (serum) and forensic blood samples a significant difference between all groups could be detected (p<0.05). Comparison of blood and urine 1,5-AG concentrations in clinical samples (linear, R2=0.13) and forensic samples (linear, R2=0.02) showed no correlation.

Keywords: 1,5-Anhydro-d-glucitol; Ante mortem; Diabetes mellitus; LC–MS/MS; Post mortem; Urine.

PubMed Disclaimer

LinkOut - more resources