. 2018 Jan 16;15(1):134-137.
doi: 10.1016/j.jor.2018.01.008. eCollection 2018 Mar.

Effect of stem alignment on long-term outcomes of total hip arthroplasty with cementless Bi-Metric femoral components

Affiliations

Effect of stem alignment on long-term outcomes of total hip arthroplasty with cementless Bi-Metric femoral components

Takaaki Shishido et al. J Orthop. .

Abstract

We investigated the effects of varus-valgus alignment on the long-term outcomes after cementless total hip arthroplasty (THA) using a porous coated version of Bi-Metric® femoral stems. The Kaplan-Meier survival analysis was performed in 71 hips. The survival rate with femoral revision for aseptic loosening as the end point was 100% at 17 years. Nevertheless, the initial stem alignment was more valgus in patients with the Engh grade III-IV stress shielding than patients with the Engh grade I-II. Our results suggest that valgus misalignment of cementless Bi-Metric stem might be a potential risk factor for the progression of stress shielding.

Keywords: Cementless THA; Femoral stem; Stem alignment; Stress shielding; Survival rate.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Kaplan-Meier survival curves for cementless Bi-Metric femoral components at a mean of 14 years.
Fig. 2
Fig. 2
Relationship between number (percentage) of the hips and the initial stem alignment.
Fig. 3
Fig. 3
Relationship between number (percentage) of the hips and the stress shielding grades defined by Engh et al. [13].
Fig. 4
Fig. 4
Relationship between the initial stem alignment and the stress shielding grades defined by Engh et al. [13].

Similar articles

Cited by

References

    1. Aldinger P.R., Breusch S.J., Lukoschek M., Mau H., Ewerbeck V., Thomsen M. A ten- to 15-year follow-up of the cementless spotorno stem. J Bone Jt Surg Br. 2003;85(2):209–214. - PubMed
    1. Pospischill M., Knahr K. Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. J Bone Jt Surg Br. 2005;87(2):1210–1215. - PubMed
    1. Berend K.R., Lombardi A.V., Mallory T.H., Dodds K.L., Adams J.B. Cementless double-tapered total hip arthroplasty in patients 75 years of age and older. J Arthroplasty. 2004;19(3):288–295. - PubMed
    1. Pieringer H., Labek G., Auersperg V., Böhler N. Cementless total hip arthroplasty in patients older than 80 years of age. J Bone Jt Surg Br. 2003;85(5):641–645. - PubMed
    1. Robeltsen K., Gaarden M., Teichert G., Langhoff O. Results of the total bi-metric cementless hip adthroplasty. Orthopedics. 1996;19(8):673–674. - PubMed

LinkOut - more resources