Safety and accuracy of spinal instrumentation surgery in a hybrid operating room with an intraoperative cone-beam computed tomography

Affiliations

Safety and accuracy of spinal instrumentation surgery in a hybrid operating room with an intraoperative cone-beam computed tomography

Christian A Bohoun et al. Neurosurg Rev. 2019 Jun.

Abstract

Although spinal instrumentation technique has undergone revolutionary progress over the past few decades, it may still carry significant surgery-related risks. The purpose of the present study was to assess the radiological accuracy of spinal screw instrumentation using a hybrid operating room (OR) and quantify the related radiation exposure. This retrospective study included 33 cases of complex spine fusion surgeries that were conducted using a hybrid OR with a flat panel detector (FPD) angiography system. Twelve cases (36.4%) were cervical, and 21 (63.6%) were thoracolumbar. The average number of spine fusion levels was 3 and 4.8, respectively, at the cervical and thoracolumbar spine levels. A FPD angiography system was used for intraoperative cone-beam computed tomography (CBCT) to obtain multi-slice spine images. All operations were conducted under optimized radiation shielding. Entrance surface doses (ESDs) and exposure times were recorded in all cases. A total of 313 screws were placed. Satisfactory screw insertion could be achieved in all cases with safe screw placement in 97.4% and acceptable placement in 2.6%. None of the cases showed any significant anatomical violation by the screws. The radiation exposure to the patients was absolutely consistent with the desired ESD value, and that to the surgeons, under the annual dose limit. These results suggest that the hybrid OR with a FPD angiography system is helpful to achieve safe and precise spinal fusion surgery, especially in complex cases.

Keywords: Cone-beam CT; Hybrid operating room; Radiation exposure; Spinal instrumentation; Surgical safety.

PubMed Disclaimer

References

    1. Br J Radiol. 1998 Dec;71(852):1288-95 - PubMed
    1. Spine (Phila Pa 1976). 2000 Apr 15;25(8):962-9 - PubMed
    1. Br J Radiol. 2001 Aug;74(884):727-34 - PubMed
    1. Eur Spine J. 2002 Dec;11(6):594-8 - PubMed
    1. Spine (Phila Pa 1976). 2003 Jan 1;28(1):91-7 - PubMed

MeSH terms

LinkOut - more resources