Pulmonary cement embolism following cement-augmented fenestrated pedicle screw fixation in adult spinal deformity patients with severe osteoporosis (analysis of 2978 fenestrated screws)
- PMID: 29671110
- DOI: 10.1007/s00586-018-5593-1
Pulmonary cement embolism following cement-augmented fenestrated pedicle screw fixation in adult spinal deformity patients with severe osteoporosis (analysis of 2978 fenestrated screws)
Abstract
Introduction: There is very limited information about pulmonary cement embolism (PCE) following cement-augmented fenestrated pedicle screw (CAFPS) fixation in the literature. The aim of this study to report the incidence of PCE following CAFPS fixation in adult deformity patients with severe osteoporosis and to identify risk factors such as; the number of levels, number of screws, and the cement volume used.
Methods: 281 patients (204F, 77M) in whom CAFPS fixation was used during deformity surgery were included. All patients' routine postop 2 day chest X-rays and any available CT scans were reviewed by two radiologists. In patients with PCE, preop, early postop, and latest echocardiography studies were compared in terms of changes in pulmonary artery pressure (PAP) and right ventricular dilatation. Estimated cement volume used was calculated as: 2 cc (1 cc + 1 cc) per thoracic and 3 cc (1.5 cc + 1.5 cc) per lumbar levels, which are our routine protocol. Statistical analysis for risk factors was assessed with point biserial correlation test.
Results: Average age is 70.5 (51-89) and average follow-up is 3.2 years (2-5). A total of 2978 CAFPS were instrumented with a mean of 10.5 levels (2-16) in 281 patients. PCE was diagnosed radiologically in 46 patients (16.3%). Among these 46 patients, PCE was clinically symptomatic in only 4 patients. Overall incidence of symptomatic PCE was 1.4% (4 of 281). Symptomatic PCE was statistically significant: when CAFPS fixation was performed > 7 levels; > 14 screws were used, and > 20-25 cc cement was used for augmentation (r = 0.378). In PCE group, mean preop PAP values of 27.40 (20-37) mm/Hg increased to 32.34 (20-50) mm/Hg in early postop and decreased to 28.29 (18-49) mm/Hg at final follow-up. In symptomatic PCE patients, mean preop PAP values of 30.75 (28-36) mm/Hg increased to 45.74 (40-50) mm/Hg in early postop and decreased to 38.75 (37-40) mm/Hg at final follow-up.
Conclusion: This study showed an overall 16.3% radiological PCE and 1.4% symptomatic PCE incidence when CAFPS were used due to severe osteoporosis. The symptomatic PCE risk was significant when CAFPS were > 7 levels; > 14 fenestrated screws; and > 20-25 cc cement volume is used and this may cause PAP increase and right ventricular dilatation.
Keywords: Fenestrated pedicle screw; Osteoporotic spine; Pulmonary cement embolism.
Similar articles
-
Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine.Spine J. 2017 Jun;17(6):837-844. doi: 10.1016/j.spinee.2017.01.009. Epub 2017 Jan 17. Spine J. 2017. PMID: 28108403
-
Fenestrated pedicle screws for thoracolumbar instrumentation in patients with poor bone quality: Case series and systematic review of the literature.Clin Neurol Neurosurg. 2021 Jul;206:106675. doi: 10.1016/j.clineuro.2021.106675. Epub 2021 May 11. Clin Neurol Neurosurg. 2021. PMID: 34020324
-
Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease.BMC Musculoskelet Disord. 2020 Apr 28;21(1):274. doi: 10.1186/s12891-020-03309-y. BMC Musculoskelet Disord. 2020. PMID: 32345282 Free PMC article.
-
Minimally invasive spinal fixation in an aging population with osteoporosis: clinical and radiological outcomes and safety of expandable screws versus fenestrated screws augmented with polymethylmethacrylate.Neurosurg Focus. 2020 Aug;49(2):E14. doi: 10.3171/2020.5.FOCUS20232. Neurosurg Focus. 2020. PMID: 32738795 Clinical Trial.
-
Cardiopulmonary Cement Embolism Following Cement-Augmented Pedicle Screw Fixation: A Narrative Review.Medicina (Kaunas). 2023 Feb 19;59(2):407. doi: 10.3390/medicina59020407. Medicina (Kaunas). 2023. PMID: 36837608 Free PMC article. Review.
Cited by
-
Cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine - A case report.Surg Neurol Int. 2024 Aug 16;15:290. doi: 10.25259/SNI_506_2024. eCollection 2024. Surg Neurol Int. 2024. PMID: 39246758 Free PMC article.
-
Symptomatic pulmonary cement embolism after pedicle screw polymethylmethacrylate cement augmentation: A case report and review.Surg Neurol Int. 2020 Feb 7;11:18. doi: 10.25259/SNI_592_2019. eCollection 2020. Surg Neurol Int. 2020. PMID: 32123606 Free PMC article.
-
Comparison of cement-augmented pedicle screw and conventional pedicle screw for the treatment of lumbar degenerative patients with osteoporosis.Eur J Orthop Surg Traumatol. 2024 Apr;34(3):1609-1617. doi: 10.1007/s00590-024-03849-2. Epub 2024 Feb 16. Eur J Orthop Surg Traumatol. 2024. PMID: 38363348
-
The Biomechanical Properties of Cement-Augmented Pedicle Screws for Osteoporotic Spines.Global Spine J. 2022 Mar;12(2):323-332. doi: 10.1177/2192568220987214. Epub 2021 Feb 22. Global Spine J. 2022. PMID: 33611971 Free PMC article.
-
A Novel Calcium Phosphate-Based Nanocomposite for Augmentation of Cortical Bone Trajectory Screw Fixation.Int J Nanomedicine. 2022 Jul 9;17:3059-3071. doi: 10.2147/IJN.S365149. eCollection 2022. Int J Nanomedicine. 2022. PMID: 35844971 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical