Fluorodeoxyglucose positron emission tomography imaging for diagnosing periprosthetic hip infection: the importance of diagnostic criteria
- PMID: 29679108
- DOI: 10.1007/s00264-018-3931-x
Fluorodeoxyglucose positron emission tomography imaging for diagnosing periprosthetic hip infection: the importance of diagnostic criteria
Abstract
Background: Fluorodeoxyglucose positron emission tomography (FDG-PET) is a novel method of assessing suspected periprosthetic hip infection. However, a heterogeneity of sensitivity and specificity using different diagnostic criteria across clinical studies has been published. The objective of this study is to evaluate the various diagnostic criteria using FDG-PET in diagnosing periprosthetic hip infection.
Methods: FDG-PET scans of patients suffering from painful hip prostheses between 2008 and 2015 were retrospectively reviewed. The PET images were considered positive for infection using five criteria: any increased uptake at the (1) bone-prosthesis-interface, (2) periprosthetic soft tissue (PST), or (3) both, (4) increased uptake in the bone-prosthesis-interface compared to the PST, and (5) increased uptake along the femoral bone-prosthesis-interface. The final diagnosis of infection was based on the pre-operative and intra-operative findings with clinical follow-up > 12 months.
Results: A total of 33 hip prostheses were evaluated in this study, of which 16 were determined to be infected and 17 uninfected. Any periprosthetic FDG uptake was found in all symptomatic prostheses (sensitivity 100%; specificity 0%). When increased uptake in the bone-prosthesis-interface (sensitivity 100%; specificity 65%) or PST (sensitivity 94%; specificity 59%) was considered infected, specificity increased. A higher intensity of uptake at the bone-prosthesis-interface than PST demonstrated only moderate specificity (sensitivity 44%; specificity 71%). The most specific criterion for infection was an increased FDG uptake along the femoral bone-prosthesis-interface (sensitivity 81%; specificity 94%).
Conclusions: Our results demonstrated that the accuracy of FDG-PET is highly dependent of the diagnostic criteria used for periprosthetic hip infection. Only an acceptable diagnostic accuracy (sensitivity 81%; specificity 94%) was found when increased FDG uptake along the femoral bone-prosthesis-interface was considered positive for infection.
Keywords: FDG-PET; Infected hip arthroplasty; Infected hip prosthesis; Nuclear imaging; Periprosthetic joint infection; Positron-emission tomography; Prosthesis-related infections/diagnostic imaging; Prosthesis-related infections/microbiology.
Similar articles
-
The importance of the location of fluorodeoxyglucose uptake in periprosthetic infection in painful hip prostheses.Nucl Med Commun. 2002 Sep;23(9):851-5. doi: 10.1097/00006231-200209000-00008. Nucl Med Commun. 2002. PMID: 12195089 Clinical Trial.
-
FDG-PET imaging can diagnose periprosthetic infection of the hip.Clin Orthop Relat Res. 2008 Jun;466(6):1338-42. doi: 10.1007/s11999-008-0237-0. Epub 2008 Apr 18. Clin Orthop Relat Res. 2008. PMID: 18421537 Free PMC article. Clinical Trial.
-
The use of [18 F]fluorodeoxyglucose positron emission tomography to differentiate between synovitis, loosening and infection of hip and knee prostheses.Nucl Med Commun. 2002 Jul;23(7):645-53. doi: 10.1097/00006231-200207000-00009. Nucl Med Commun. 2002. PMID: 12089487 Clinical Trial.
-
18F-FDG PET in the Diagnosis of Vascular Prosthetic Graft Infection: A Diagnostic Test Accuracy Meta-Analysis.Eur J Vasc Endovasc Surg. 2019 Feb;57(2):292-301. doi: 10.1016/j.ejvs.2018.08.040. Epub 2018 Sep 18. Eur J Vasc Endovasc Surg. 2019. PMID: 30241981 Review.
-
A systematic review and meta-analysis of 18F-fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography for detection of infected prosthetic vascular grafts.J Vasc Surg. 2019 Jul;70(1):307-313. doi: 10.1016/j.jvs.2019.01.051. Epub 2019 Mar 25. J Vasc Surg. 2019. PMID: 30922755
Cited by
-
Candida periprosthetic infection of the hip: a systematic review of surgical treatments and clinical outcomes.Int Orthop. 2020 Jan;44(1):15-22. doi: 10.1007/s00264-019-04369-z. Epub 2019 Jun 28. Int Orthop. 2020. PMID: 31254016
-
Medical imaging diagnosis of orthopedic prosthesis-associated infections: a narrative review.Quant Imaging Med Surg. 2025 Jan 2;15(1):947-961. doi: 10.21037/qims-24-403. Epub 2024 Nov 15. Quant Imaging Med Surg. 2025. PMID: 39839020 Free PMC article. Review.
-
Is 18 F-fluoride PET/CT an Accurate Tool to Diagnose Loosening After Total Joint Arthroplasty?Clin Orthop Relat Res. 2025 Mar 1;483(3):415-428. doi: 10.1097/CORR.0000000000003228. Epub 2024 Sep 11. Clin Orthop Relat Res. 2025. PMID: 39293088
-
Diagnostic accuracy of positron emission tomography/computerized tomography for periprosthetic joint infection of hip: systematic review and meta-analysis.J Orthop Surg Res. 2023 Aug 30;18(1):640. doi: 10.1186/s13018-023-04061-4. J Orthop Surg Res. 2023. PMID: 37644493 Free PMC article.
-
18F FDG-PET/CT has poor diagnostic accuracy in diagnosing shoulder PJI.Eur J Nucl Med Mol Imaging. 2019 Sep;46(10):2013-2022. doi: 10.1007/s00259-019-04381-w. Epub 2019 Jul 11. Eur J Nucl Med Mol Imaging. 2019. PMID: 31292698
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources