Wire-loop technique for angioplasty of total iliac artery occlusions
- PMID: 2967988
- DOI: 10.1148/radiology.168.1.2967988
Wire-loop technique for angioplasty of total iliac artery occlusions
Abstract
To recanalize occlusions of the iliac artery from an ipsilateral approach, the authors developed a technique in which the guide wire is manipulated through puncture sites in both sides of the groin. This technique was used in four occlusions (three in the common iliac artery and one in the external iliac artery); all occlusions were successfully dilated with balloon catheters. In two cases in which dilation was performed from the contralateral side, the contralateral iliac artery became occluded after the procedure. These occlusions were successfully dilated.
Similar articles
-
Pull-through approach to percutaneous angioplasty of totally occluded common iliac arteries.Radiology. 1989 Jul;172(1):111-3. doi: 10.1148/radiology.172.1.2525789. Radiology. 1989. PMID: 2525789
-
Common iliac artery occlusion: treatment with pull-through angioplasty.Radiology. 1988 Jul;168(1):273-4. doi: 10.1148/radiology.168.1.2967987. Radiology. 1988. PMID: 2967987
-
[Recanalization of an iliac artery occlusion from the contralateral side using "low-speed rotational angioplasty"].Z Kardiol. 1991 Apr;80(4):290-3. Z Kardiol. 1991. PMID: 1830714 German.
-
[Percutaneous transluminal angioplasty of iliac occlusions].Ugeskr Laeger. 1995 May 22;157(21):3042-5. Ugeskr Laeger. 1995. PMID: 7792957 Danish.
-
Iliac artery angioplasty : technique and results.Acta Chir Belg. 2004 Oct;104(5):532-9. doi: 10.1080/00015458.2004.11679610. Acta Chir Belg. 2004. PMID: 15571019 Review.
Cited by
-
Total occlusion of iliac arteries: results of balloon angioplasty.Cardiovasc Intervent Radiol. 1993 May-Jun;16(3):165-77. doi: 10.1007/BF02641886. Cardiovasc Intervent Radiol. 1993. PMID: 8334688
-
New device for wire and catheter capturing: in vivo experiments and first clinical experience.Cardiovasc Intervent Radiol. 1995 Sep-Oct;18(5):312-4. doi: 10.1007/BF00203682. Cardiovasc Intervent Radiol. 1995. PMID: 8846471
-
Crossover approach with a J-shaped sheath for angioplasty of iliofemoral artery stenoses and occlusions.Cardiovasc Intervent Radiol. 1995 Mar-Apr;18(2):125-8. doi: 10.1007/BF02807238. Cardiovasc Intervent Radiol. 1995. PMID: 7773996
-
Modified crossover and guidewire loop technique for double-balloon angioplasty of the aortic bifurcation.Cardiovasc Intervent Radiol. 1994 Mar-Apr;17(2):116-8. doi: 10.1007/BF00193930. Cardiovasc Intervent Radiol. 1994. PMID: 8013025
-
Balloon-hooking technique for stabilizing a guiding catheter in tortuous supra-aortic vessel: A case report.Radiol Case Rep. 2022 Aug 16;17(10):3966-3970. doi: 10.1016/j.radcr.2022.07.086. eCollection 2022 Oct. Radiol Case Rep. 2022. PMID: 35991386 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources