99mTc-MAG3: dynamic studies in patients with renal disease
- PMID: 2968259
- DOI: 10.1007/BF00252614
99mTc-MAG3: dynamic studies in patients with renal disease
Abstract
Animal studies have suggested that 99mTc-mercapto-acetylglycyl-glycyl-glycine (99mTc-MAG3) might be suitable for the determination of the renal plasma flow (RPF) because of its high renal clearance. In this study 131I-orthoiodohippurate (131I-OIH) and 99mTc-MAG3 (labeling always greater than 95%) were administered simultaneously in 11 patients (creatinine clearance ranging from 14 to 130 ml/min per 1.73 m2) to measure effective RPF(ERPF) using the standard technique (UV/P). Glomerular filtration rate (GFR; clearance of 125I-thalamate, 125I-OT) was also measured. The mean ratio of 99mTc-MAG3 clearance to 131I-IOH clearance was 0.55 +/- 0.02 (SEM), P less than 0.01, n = 16, and was independent of GFR and ERPF. To study this difference in renal handling of the radiopharmaceuticals, renal extractions by the right kidney were determined in another six patients after a single shot of the agents. Renal extraction of 99mTc-MAG3 was 0.60 +/- 0.03 after 5 min, and 0.41 +/- 0.08 after 30 min. Renal extraction of 131I-OIH amounted to 0.86 +/- 0.04 and 0.77 +/- 0.03, respectively. Using renal extractions of 0.41 and 0.77, respectively, it appeared that calculated renal plasma flows measured simultaneously with 99mTc-MAG3 and 131I-OIH were similar. Protein binding 30 min after the priming dose was 66% for 99mTc-MAG3 and 47% for 123I-OIH. We conclude that in spite of a high renal clearance (ratio to 125I-OT clearance 2.69 +/- 0.27), 99mTc-MAG3 seems unsuitable for an accurate determination of the RPF.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Renal and extrarenal clearance of 99mTc-MAG3: a comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular filtration rate.Eur J Nucl Med. 1995 Dec;22(12):1379-84. doi: 10.1007/BF01791145. Eur J Nucl Med. 1995. PMID: 8586082
-
99mTc-MAG3 versus 131I-orthoiodohippurate in the routine determination of effective renal plasma flow.J Nucl Med Allied Sci. 1990 Apr-Jun;34(2):67-70. J Nucl Med Allied Sci. 1990. PMID: 2147211
-
Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats.J Nucl Med. 1987 Dec;28(12):1881-7. J Nucl Med. 1987. PMID: 2960790
-
Technetium-99m (99mTc) mercaptoacetyltriglycine: update on the new 99mTc renal tubular function agent.Semin Nucl Med. 1992 Apr;22(2):61-73. doi: 10.1016/s0001-2998(05)80082-0. Semin Nucl Med. 1992. PMID: 1534184 Review.
-
99mTc renal tubular function agents: current status.Semin Nucl Med. 1990 Jan;20(1):28-40. doi: 10.1016/s0001-2998(05)80174-6. Semin Nucl Med. 1990. PMID: 2136959 Review.
Cited by
-
Assessment of Individual Renal Function Using 99mTc-MAG3 Renography.In Vivo. 2022 Jan-Feb;36(1):206-211. doi: 10.21873/invivo.12692. In Vivo. 2022. PMID: 34972716 Free PMC article.
-
SNMMI Procedure Standard/EANM Practice Guideline for Diuretic Renal Scintigraphy in Adults With Suspected Upper Urinary Tract Obstruction 1.0.Semin Nucl Med. 2018 Jul;48(4):377-390. doi: 10.1053/j.semnuclmed.2018.02.010. Epub 2018 Mar 16. Semin Nucl Med. 2018. PMID: 29852947 Free PMC article. No abstract available.
-
Dynamic renal scanning using 99mTc-MAG-3 in man.Eur J Nucl Med. 1989;15(10):635-40. doi: 10.1007/BF00251675. Eur J Nucl Med. 1989. PMID: 2530091
-
Renal and extrarenal clearance of 99mTc-MAG3: a comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular filtration rate.Eur J Nucl Med. 1995 Dec;22(12):1379-84. doi: 10.1007/BF01791145. Eur J Nucl Med. 1995. PMID: 8586082
-
(99m)Tc(CO)3(NTA): a (99m)Tc renal tracer with pharmacokinetic properties comparable to those of (131)I-OIH in healthy volunteers.J Nucl Med. 2010 Mar;51(3):391-6. doi: 10.2967/jnumed.109.070813. Epub 2010 Feb 11. J Nucl Med. 2010. PMID: 20150248 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Medical