Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1988;14(1):28-31.
doi: 10.1007/BF00252614.

99mTc-MAG3: dynamic studies in patients with renal disease

Affiliations
Comparative Study

99mTc-MAG3: dynamic studies in patients with renal disease

G H Schaap et al. Eur J Nucl Med. 1988.

Abstract

Animal studies have suggested that 99mTc-mercapto-acetylglycyl-glycyl-glycine (99mTc-MAG3) might be suitable for the determination of the renal plasma flow (RPF) because of its high renal clearance. In this study 131I-orthoiodohippurate (131I-OIH) and 99mTc-MAG3 (labeling always greater than 95%) were administered simultaneously in 11 patients (creatinine clearance ranging from 14 to 130 ml/min per 1.73 m2) to measure effective RPF(ERPF) using the standard technique (UV/P). Glomerular filtration rate (GFR; clearance of 125I-thalamate, 125I-OT) was also measured. The mean ratio of 99mTc-MAG3 clearance to 131I-IOH clearance was 0.55 +/- 0.02 (SEM), P less than 0.01, n = 16, and was independent of GFR and ERPF. To study this difference in renal handling of the radiopharmaceuticals, renal extractions by the right kidney were determined in another six patients after a single shot of the agents. Renal extraction of 99mTc-MAG3 was 0.60 +/- 0.03 after 5 min, and 0.41 +/- 0.08 after 30 min. Renal extraction of 131I-OIH amounted to 0.86 +/- 0.04 and 0.77 +/- 0.03, respectively. Using renal extractions of 0.41 and 0.77, respectively, it appeared that calculated renal plasma flows measured simultaneously with 99mTc-MAG3 and 131I-OIH were similar. Protein binding 30 min after the priming dose was 66% for 99mTc-MAG3 and 47% for 123I-OIH. We conclude that in spite of a high renal clearance (ratio to 125I-OT clearance 2.69 +/- 0.27), 99mTc-MAG3 seems unsuitable for an accurate determination of the RPF.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Nucl Med. 1981 Apr;22(4):333-8 - PubMed
    1. J Nucl Med. 1986 Jan;27(1):111-6 - PubMed
    1. J Nucl Med. 1986 Jun;27(6):795-803 - PubMed
    1. Neth J Med. 1977;20(3):97-103 - PubMed
    1. J Nucl Med. 1980 Feb;21(2):168-70 - PubMed

Publication types

LinkOut - more resources