Failure to place a tunneled hemodialysis catheter due to malformation of right internal jugular vein draining to subclavian vein
- PMID: 29690817
- PMCID: PMC6023040
- DOI: 10.1177/0300060518766649
Failure to place a tunneled hemodialysis catheter due to malformation of right internal jugular vein draining to subclavian vein
Abstract
The right internal jugular vein (IJV) is an important access site for hemodialysis catheterization. Venous cannulation failure is usually caused by central venous stenosis and is rarely related to vessel malformation. We herein present a case of failure to place a tunneled hemodialysis catheter into the right IJV. The patient had an arteriovenous fistula in the right arm with inadequate flow and a history of multiple central venous catheterizations. The guidewire was repeatedly misplaced into the right subclavian vein (SV) regardless of the technique used. Computed tomography venography revealed that the inferior segment of the right IJV drained into the ipsilateral SV. To the best of our knowledge, this is the first report of catheterization failure due to abnormal drainage of the right IJV into the ipsilateral SV.
Keywords: Renal dialysis; catheterization; central vein; malformation; right internal jugular vein; subclavian vein.
Figures
References
-
- Wu S and Kalva S. Dialysis access management. Basel: Springer International Publishing, 2015.
-
- Kumwenda M, Mitra S and Reid C. Clinical practice guideline vascular access for haemodialysis: UK renal association 6th edition final version, 2015. - PubMed
-
- Watanabe Y, Yamagata K, Nishi S, et al. Japanese society for dialysis therapy clinical guideline for “hemodialysis initiation for maintenance hemodialysis”. Ther Apher Dial 2015; 19(Suppl 1): 93–107. - PubMed
-
- Calvino J, Bravo J, Martinez L, et al. Recognizing misplacement of a dialysis catheter in the azygos vein. Hemodial Int 2013; 17: 455–457. - PubMed