Retrospective validation of the laparoscopic ICG SLN mapping in patients with grade 3 endometrial cancer
- PMID: 29691646
- PMCID: PMC11813295
- DOI: 10.1007/s00432-018-2648-y
Retrospective validation of the laparoscopic ICG SLN mapping in patients with grade 3 endometrial cancer
Abstract
Purpose: To evaluate the sensitivity, negative predictive value (NPV) and false-negative (FN) rate of the near infrared (NIR) indocyanine green (ICG) sentinel lymph node (SLN) mapping in patients with poorly differentiated endometrial cancer who have undergone a full pelvic and para-aortic lymphadenectomy after SLN mapping.
Methods: We performed a retrospective analysis of patients with endometrial cancer undergoing a laparoscopic NIR-ICG SLN mapping followed by a systematic pelvic and para-aortic lymphadenectomy. Inclusion criteria were a grade 3 endometrial cancer or a high-risk histology (papillary serous, clear cell carcinoma, carcinosarcoma, and neuroendocrine carcinoma) and a completion pelvic and para-aortic lymphadenectomy to the renal vessels after SLN mapping. Overall and bilateral detection rates, sensitivity, NPV, and FN rates were calculated.
Results: From December 2012 until January 2017, 42 patients fulfilled inclusion criteria. Overall and bilateral detection rates were 100 and 90.5%, respectively. Overall, 23.8% of the patients had lymph node metastases. In one patient, despite negative bilateral pelvic SLNs, a metastatic non-SLN-isolated para-aortic metastasis was detected. This NSLN was clinically suspicious and sent to frozen section analysis during the surgery. FN rate, sensitivity, and NPV were 10, 90, and 97.1%, respectively. For the SLN mapping algorithm, FN rate, sensitivity, and NPV were 0, 100, and 100%, respectively.
Conclusions: Laparoscopic NIR-ICG SLN mapping in high-risk endometrial cancer patients has acceptable sensitivity, FN rate, and NPV.
Keywords: Carcinosarcomas; Clear cell carcinoma; Endometrial cancer; Grade 3; Sentinel lymph node biopsy; Uterine papillary serous carcinoma.
Conflict of interest statement
None of the authors have any conflict of interest.
Figures
References
-
- Buda A, Papadia A, Zapardiel I, Vizza E, Ghezzi F, De Ponti E, Lissoni AA, Imboden S, Diestro MD, Verri D, Gasparri ML, Bussi B, Di Martino G, de la Noval BD, Mueller M, Crivellaro C (2016) From conventional radiotracer Tc-99(m) with blue dye to indocyanine green fluorescence: a comparison of methods towards optimization of sentinel lymph node mapping in early stage cervical cancer for a laparoscopic approach. Ann Surg Oncol 23:2959–2965 - DOI - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous
