[Doppler study of phasic variations of blood flow velocity in the anterior interventricular artery]
- PMID: 2969225
[Doppler study of phasic variations of blood flow velocity in the anterior interventricular artery]
Abstract
Studies of changes in coronary blood flow during cardiac cycles may be a useful adjuvant to the measurement of coronary flow reserve to evaluate the hydraulic severity of coronary arterial stenoses. We used intracoronary pulsed Doppler velocimetry to measure phasic variations of blood flow in the anterior interventricular artery of 12 patients with angiographically identified stenosis of that vessel. The Doppler signal was obtained by means of a 20 MHz emission from a source placed at the tip of a catheter selectively positioned at the ostium of the anterior interventricular artery, upstream of the stenosis. The increase in severity of stenosis was paralleled by a relative decrease of diastolic blood flow velocity in relation to systolic blood flow velocity. The diastolic/systolic maximum velocities ratio was greater than 1 in 6 patients with a less than 70 p. 100 stenosis (group A) and inferior to 1 in 6 other patients with a 70 p. 100 or more stenosis (group B). In 5 patients of group B this ratio was reversed to normal after percutaneous transluminal angiography. Thus, measurement of intracoronary blood flow velocity may be helpful to evaluate the severity of stenosis, notably in the anterior interventricular artery where angiographic evaluation is difficult.
Similar articles
-
[Intracoronary blood flow velocity during angioplasty. Functional guide and indicator of the success of dilatation].Arch Mal Coeur Vaiss. 1987 Nov;80(12):1725-33. Arch Mal Coeur Vaiss. 1987. PMID: 2965559 French.
-
[Coronary blood flow velocities in humans evaluated during cardiac surgery using a 20 MHz 80 + 1 channel ultrasound pulsed Doppler velocimeter].J Cardiogr. 1986 Jun;16(2):279-90. J Cardiogr. 1986. PMID: 2953822 Japanese.
-
Angiographical and Doppler flow-derived parameters for assessment of coronary lesion severity and its relation to the result of exercise electrocardiography. DEBATE study group. Doppler Endpoints Balloon Angioplasty Trial Europe.Eur Heart J. 2000 Mar;21(6):466-74. doi: 10.1053/euhj.1999.1871. Eur Heart J. 2000. PMID: 10681487
-
[Evaluation of functional importance of coronary artery stenosis by intracoronary Doppler blood flow velocity measurement].Ugeskr Laeger. 1998 Jun 29;160(27):4050-4. Ugeskr Laeger. 1998. PMID: 9659833 Review. Danish.
-
[Measurements of intracoronary pressure and blood flow velocity].Praxis (Bern 1994). 1997 Apr 16;86(16):649-54. Praxis (Bern 1994). 1997. PMID: 9221468 Review. German.