Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jun 25;56(7):e00386-18.
doi: 10.1128/JCM.00386-18. Print 2018 Jul.

Development and Evaluation of a Novel Loop-Mediated Isothermal Amplification Assay for Diagnosis of Cutaneous and Visceral Leishmaniasis

Affiliations

Development and Evaluation of a Novel Loop-Mediated Isothermal Amplification Assay for Diagnosis of Cutaneous and Visceral Leishmaniasis

Emily Rebecca Adams et al. J Clin Microbiol. .

Abstract

A novel pan-Leishmania loop-mediated isothermal amplification (LAMP) assay for the diagnosis of cutaneous and visceral leishmaniasis (CL and VL) that can be used in near-patient settings was developed. Primers were designed based on the 18S ribosomal DNA (rDNA) and the conserved region of minicircle kinetoplast DNA (kDNA), selected on the basis of high copy number. LAMP assays were evaluated for CL diagnosis in a prospective cohort trial of 105 patients in southwest Colombia. Lesion swab samples from CL suspects were collected and were tested using the LAMP assay, and the results were compared to those of a composite reference of microscopy and/or culture in order to calculate diagnostic accuracy. LAMP assays were tested on samples (including whole blood, peripheral blood mononuclear cells, and buffy coat) from 50 suspected VL patients from Ethiopia. Diagnostic accuracy was calculated against a reference standard of microscopy of splenic or bone marrow aspirates. To calculate analytical specificity, 100 clinical samples and isolates from fever-causing pathogens, including malaria parasites, arboviruses, and bacteria, were tested. We found that the LAMP assay had a sensitivity of 95% (95% confidence interval [CI], 87.2% to 98.5%) and a specificity of 86% (95% CI, 67.3% to 95.9%) for the diagnosis of CL. With VL suspects, the sensitivity of the LAMP assay was 92% (95% CI, 74.9% to 99.1%) and its specificity was 100% (95% CI, 85.8% to 100%) in whole blood. For CL, the LAMP assay is a sensitive tool for diagnosis and requires less equipment, time, and expertise than alternative CL diagnostics. For VL, the LAMP assay using a minimally invasive sample is more sensitive than the gold standard. Analytical specificity was 100%.

Keywords: LAMP; Leishmania; cutaneous; diagnostics; visceral.

PubMed Disclaimer

References

    1. Medley GF, Hollingsworth TD, Olliaro PL, Adams ER. 2015. Health-seeking behaviour, diagnostics and transmission dynamics in the control of visceral leishmaniasis in the Indian subcontinent. Nature 528:S102–S108. doi:10.1038/nature16042. - DOI - PubMed
    1. Cunningham J, Hasker E, Das P, El Safi S, Goto H, Mondal D, Mbuchi M, Mukhtar M, Rabello A, Rijal S, Sundar S, Wasunna M, Adams E, Menten J, Peeling R, Boelaert M; WHO/TDR Visceral Leishmaniasis Laboratory Network. 2012. A global comparative evaluation of commercial immunochromatographic rapid diagnostic tests for visceral leishmaniasis. Clin Infect Dis 55:1312–1319. doi:10.1093/cid/cis716. - DOI - PMC - PubMed
    1. Boelaert M, Verdonck K, Menten J, Sunyoto T, van Griensven J, Chappuis F, Rijal S. 2014. Rapid tests for the diagnosis of visceral leishmaniasis in patients with suspected disease. Cochrane Database Syst Rev 6:CD009135. doi:10.1002/14651858.CD009135.pub2. - DOI - PMC - PubMed
    1. Chappuis F, Rijal S, Soto A, Menten J, Boelaert M. 2006. A meta-analysis of the diagnostic performance of the direct agglutination test and rK39 dipstick for visceral leishmaniasis. BMJ 333:723. doi:10.1136/bmj.38917.503056.7C. - DOI - PMC - PubMed
    1. Mitarai S, Okumura M, Toyota E, Yoshiyama T, Aono A, Sejimo A, Azuma Y, Sugahara K, Nagasawa T, Nagayama N, Yamane A, Yano R, Kokuto H, Morimoto K, Ueyama M, Kubota M, Yi R, Ogata H, Kudoh S, Mori T. 2011. Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis. Int J Tuberc Lung Dis 15:1211–1217. doi:10.5588/ijtld.10.0629. - DOI - PubMed

Publication types

MeSH terms