Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2018 Oct;31(5):580-587.
doi: 10.1111/joic.12516. Epub 2018 May 1.

Impact of ultra-thin struts on restenosis after chronic total occlusion recanalization: Insights from the randomized PRISON IV trial

Affiliations
Free article
Randomized Controlled Trial

Impact of ultra-thin struts on restenosis after chronic total occlusion recanalization: Insights from the randomized PRISON IV trial

Carlo Zivelonghi et al. J Interv Cardiol. 2018 Oct.
Free article

Abstract

Objectives: The PRISON-IV trial showed inferior outcome in patients with chronic total occlusions (CTOs) treated with the ultrathin-struts (60 μm for stent diameter ≤3 mm, 81μm >3 mm) hybrid-sirolimus eluting stents (SES) compared with everolimus eluting stents (EES, 81 μm). The aim of this study is to investigate if the use of smaller stents (≤3 mm) was responsible for the inferior outcome reported in the trial.

Methods: In the PRISON-IV trial 330 patients with CTO lesion were randomized 1:1 to receive either hybrid-SES or EES. The hybrid-SES failed to reach the non-inferiority primary endpoint of in-segment late lumen loss (LLL) at 9-month angiographic follow-up. In this sub-analysis, we divided the population according to the different size of stents implanted in those receiving only stents with diameter ≤3 mm (Group-A, 178 patients), only stents >3 mm (Group-B, 59 patients), and those receiving stents of both sizes (Group-C, 93 patients).

Results: Baseline and procedural characteristics were comparable in the three groups. At angiographic follow-up, most of the adverse outcomes occurred in Group A, with higher incidence of binary restenosis in the Hybrid-SES versus EES (10.3% vs 1.3%, P = 0.03) and augmented in-stent diameter stenosis (26.04 ± 18.59% vs 21.24 ± 12.84, P = 0.06). Similarly, optical coherence tomography (OCT), which was performed in 60 patients at follow-up, documented a mild trend toward lower values of minimum in stent area in Hybrid-SES arm of Group A (4.4 ± 1.02mm2 vs 5.0 ± 1.28mm2, respectively, P = 0.16).

Conclusions: The present analysis suggests that the inferior performance of the ultra-thin hybrid-SES in CTO-PCI is particularly pronounced when smaller stent (≤3 mm diameter) are adopted, if compared with EES.

Keywords: chronic total occlusions; drug-eluting stents; ultrathin struts.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources