Optimizing ERG Measures of Scotopic and Photopic Critical Flicker Frequency
- PMID: 29721938
- DOI: 10.1007/978-3-319-75402-4_18
Optimizing ERG Measures of Scotopic and Photopic Critical Flicker Frequency
Abstract
A visual response to flickering light requires complex retinal computation, and thus ERG measures are an excellent test of retinal circuit fidelity. Critical flicker frequency (CFF) is the frequency at which the retinal response is no longer modulated. Traditionally, CFF is obtained with a series of steady flicker stimuli with increasing frequencies. However, this method is slow and susceptible to experimental drift and/or adaptational effects. The current study compares the steady flicker method to CFF measurements obtained using a frequency sweep protocol. We introduce a light source programmed to produce a linear sweep of frequencies in a single trial. Using the traditional steady flicker method and a criterion response of 3 μV, we obtained a scotopic CFF of 18.4 ± 0.66 Hz and a photopic CFF of 44.4 ± 1.67 Hz. Our sweep flicker method, used on the same animals, produces a waveform best analyzed by Fourier transform; wherein a 6.18 log μV2 threshold was found to yield CFF values equal to those of the steady flicker method. Thus, the two flicker ERG techniques give comparable results, under both dark- and light-adapted conditions, and the flicker sweep method is faster to administer and analyze and may be less susceptible to blinking, breathing, and eye movement artifacts.
Keywords: Critical flicker frequency; Electroretinography; Murine retina; Photoreceptors; Sweep flicker.
Similar articles
-
ERG and Behavioral CFF in Light-Damaged Albino Rats.Int J Mol Sci. 2022 Apr 8;23(8):4127. doi: 10.3390/ijms23084127. Int J Mol Sci. 2022. PMID: 35456959 Free PMC article.
-
ERG critical flicker frequency assessment in humans.Adv Exp Med Biol. 2012;723:503-9. doi: 10.1007/978-1-4614-0631-0_63. Adv Exp Med Biol. 2012. PMID: 22183370 Clinical Trial. No abstract available.
-
Non-selectivity of ERG reductions in eyes treated for retinoblastoma.Doc Ophthalmol. 2014 Feb;128(1):13-23. doi: 10.1007/s10633-013-9416-8. Epub 2013 Nov 9. Doc Ophthalmol. 2014. PMID: 24213436
-
Why rods and cones?Eye (Lond). 2016 Feb;30(2):179-85. doi: 10.1038/eye.2015.236. Epub 2015 Nov 13. Eye (Lond). 2016. PMID: 26563661 Free PMC article. Review.
-
A reinterpretation of critical flicker-frequency (CFF) data reveals key details about light adaptation and normal and abnormal visual processing.Prog Retin Eye Res. 2022 Mar;87:101001. doi: 10.1016/j.preteyeres.2021.101001. Epub 2021 Sep 8. Prog Retin Eye Res. 2022. PMID: 34506951 Review.
Cited by
-
Retinal Responses to Visual Stimuli in Interphotoreceptor Retinoid Binding-Protein Knock-Out Mice.Int J Mol Sci. 2023 Jun 26;24(13):10655. doi: 10.3390/ijms241310655. Int J Mol Sci. 2023. PMID: 37445836 Free PMC article.
-
Low-cost, open-source device for simultaneously subjecting rodents to different circadian cycles of light, food, and temperature.Front Physiol. 2024 Feb 16;15:1356787. doi: 10.3389/fphys.2024.1356787. eCollection 2024. Front Physiol. 2024. PMID: 38434139 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources